SAR prediction in adults and children by combining measured B1+ maps and simulations at 7.0 Tesla

Abstract: For ZTE and FLAIR, limits on maximum local and global SAR were met in all subjects, both adults and children. To enhance safety in adults and children with 7.0 Tesla MR systems, we suggest the possibility of using SAR prediction. J. MAGN. RESON. IMAGING 2016;44:1048-1055.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 22 publications
0
12
0
Order By: Relevance
“…[3][4][5][6] Additional intrinsic sequence properties include rapid imaging times, silent scanning, high-resolution isotropic datasets, and resistance to artifacts. [7][8][9] The applicability of ZTE for bone imaging has been successfully demonstrated in small clinical case series and ex vivo studies of the cranial vault, face, jaw, and spine. [12][13][14][15][16][17][18][19] Because MR imaging already provides superior soft-tissue detail, the addition of a ZTE bone sequence would enable highly efficient and radiation-free evaluation in several pediatric neuroimaging, head/neck imaging, and musculoskeletal imaging scenarios.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…[3][4][5][6] Additional intrinsic sequence properties include rapid imaging times, silent scanning, high-resolution isotropic datasets, and resistance to artifacts. [7][8][9] The applicability of ZTE for bone imaging has been successfully demonstrated in small clinical case series and ex vivo studies of the cranial vault, face, jaw, and spine. [12][13][14][15][16][17][18][19] Because MR imaging already provides superior soft-tissue detail, the addition of a ZTE bone sequence would enable highly efficient and radiation-free evaluation in several pediatric neuroimaging, head/neck imaging, and musculoskeletal imaging scenarios.…”
Section: Discussionmentioning
confidence: 99%
“…The technique uses lower changes in amplitude over time (dB/dt) than conventional sequences; low flip angles and built-in scanner safety measures counter the short RF pulse duration that would otherwise raise concern for a high specific absorption rate (SAR). 9…”
Section: Technical Considerationsmentioning
confidence: 99%
See 1 more Smart Citation
“…[49][50][51][52][53][54][55][56] A more direct and potentially more accurate approach to estimate SAR is to use actual MRI images; for example, obtaining B 1 maps that may then be used to estimate the E field and derive the SAR distribution. [57][58][59][60] It is important to note that, for the purposes of safety monitoring, SAR is merely used as a surrogate measure for the potential to cause tissue damage. The real problem is heating.…”
Section: Rf Heating Of Biological Tissuementioning
confidence: 99%
“…Attempts have been made to develop human body models that, when used with numerical simulation techniques, may give accurate estimates of SAR . A more direct and potentially more accurate approach to estimate SAR is to use actual MRI images; for example, obtaining B1 maps that may then be used to estimate the bold-italicE field and derive the SAR distribution …”
Section: The Rf Fieldmentioning