2022
DOI: 10.1002/nbm.4802
|View full text |Cite
|
Sign up to set email alerts
|

A pathway towards a two‐dimensional, bore‐mounted, volume body coil concept for ultra high‐field magnetic resonance imaging

Abstract: Lack of a body‐sized, bore‐mounted, radiofrequency (RF) body coil for ultrahigh field (UHF) magnetic resonance imaging (MRI) is one of the major drawbacks of UHF, hampering the clinical potential of the technology. Transmit field (B1) nonuniformity and low specific absorption rate (SAR) efficiencies in UHF MRI are two challenges to be overcome. To address these problems, and ultimately provide a pathway for the full clinical potential of the modality, we have designed and simulated two‐dimensional cylindrical … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 78 publications
0
2
0
Order By: Relevance
“…UHF MR was not considered in this work since our focus was on the –normally vendor‐built– body coil and very few such coils exist, so far for B070.3emnormalT$$ {B}_0\ge 7\kern0.3em \mathrm{T} $$ 3,84–90 . The key elements of the described approach can also be applied at UHF, of course, where pTx is indispensable to cope with B1+$$ {B}_1^{+} $$ inhomogeneities 7–9 …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…UHF MR was not considered in this work since our focus was on the –normally vendor‐built– body coil and very few such coils exist, so far for B070.3emnormalT$$ {B}_0\ge 7\kern0.3em \mathrm{T} $$ 3,84–90 . The key elements of the described approach can also be applied at UHF, of course, where pTx is indispensable to cope with B1+$$ {B}_1^{+} $$ inhomogeneities 7–9 …”
Section: Discussionmentioning
confidence: 99%
“…UHF MR was not considered in this work since our focus was on the -normally vendor-built-body coil and very few such coils exist, so far for B 0 ≥ 7 T. 3,[84][85][86][87][88][89][90] The key elements of the described approach can also be applied at UHF, of course, where pTx is indispensable to cope with B + 1 inhomogeneities. [7][8][9] Only static RF shimming is considered in this work, since it can be immediately applied to all existing pulse sequences and is thus the natural first step for pTx in the clinical market.…”
Section: Limitationsmentioning