2006
DOI: 10.1016/j.jchromb.2005.12.004
|View full text |Cite
|
Sign up to set email alerts
|

Sample stacking for the analysis of penicillins by microemulsion electrokinetic capillary chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
45
0
1

Year Published

2007
2007
2015
2015

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 50 publications
(47 citation statements)
references
References 38 publications
1
45
0
1
Order By: Relevance
“…Different background electrolytes have been described for PENs analysis in different matrices. The pH value used is in the interval from 3.6 to 9.2 using phosphate or borate and sodium dodecyl sulphate salts [24][25][26][27][28]. Different factors affecting the separation with the background electrolyte required evaluation.…”
Section: Optimization Of Background Electrolyte Compositionmentioning
confidence: 99%
“…Different background electrolytes have been described for PENs analysis in different matrices. The pH value used is in the interval from 3.6 to 9.2 using phosphate or borate and sodium dodecyl sulphate salts [24][25][26][27][28]. Different factors affecting the separation with the background electrolyte required evaluation.…”
Section: Optimization Of Background Electrolyte Compositionmentioning
confidence: 99%
“…In addition, I noticed that the peak widths of the signals in the electropherograms for both sizes of Au NPs were reduced slightly when the REPSM voltage processes were applied, suggesting that the Au NPs in the sample underwent stacking during the application of the REPSM; the finding is consistent with those of previous reports. 37,38 After completing the REPSM, the voltage was applied (positive polarity) for various MEKC time intervals and then pressure (50 mbar) was applied to mobilize the Au NP zones to the detector. Sets (a) and (b) in Fig.…”
Section: Mechanism Of On-line Concentration and Separation Of Au Npsmentioning
confidence: 99%
“…Sample 'stacking' is a technique where improved separation efficiencies and detector response are obtained when using a sample diluent of lesser ionic strength than the microemulsion running buffer [31,67]. This technique has been used for the analysis of penicillins by MEEKC [68] and resulted in a 40-fold increase in detection limits. Sample stacking was used as an online preconcentration technique when analysing cephalosporins by MEEKC [69].…”
Section: Sample Diluent and Injectionmentioning
confidence: 99%
“…Recent methods to improve sensitivity and LODs have included sample stacking [68] to improve sensitivity up to 40-fold, and LIF detection (LIFD) [54,75], used for to achieve LODs of 5.3 and 3.9 ng/ml ephedrine and pseudoephedrine, respectively in Chinese herbal remedies [75].…”
Section: Improved Sensitivity and Detection Limitsmentioning
confidence: 99%
See 1 more Smart Citation