2017
DOI: 10.1007/s10404-017-1976-6
|View full text |Cite
|
Sign up to set email alerts
|

Sample preparation of chemical warfare agent simulants on a digital microfluidic (DMF) device using magnetic bead-based solid-phase extraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 40 publications
0
4
0
Order By: Relevance
“…successfully extracted chemical warfare agent stimulants using magnetic-bead-based SPE on a completely automated EWOD-MS device [102]. Based on the two plate configuration, the EWOD chip consisted of 14 actuation electrodes and 6 reservoir electrodes to which the sample solution was loaded.…”
Section: Sample Purification and Separationmentioning
confidence: 99%
See 2 more Smart Citations
“…successfully extracted chemical warfare agent stimulants using magnetic-bead-based SPE on a completely automated EWOD-MS device [102]. Based on the two plate configuration, the EWOD chip consisted of 14 actuation electrodes and 6 reservoir electrodes to which the sample solution was loaded.…”
Section: Sample Purification and Separationmentioning
confidence: 99%
“…These outstanding characteristic features have enabled the integration of EWOD chips with mass spectrometry (MS) for the analysis of small molecules that are limited by volume. To date, EWOD-MS coupled models have been mostly used as a sample preparation tool for the characterization of chemical and biological species present in food, water and beverage samples, rendering them important for food safety applications [ 71 , 83 , 102 104 ]. A novel prototype was proposed by Gorbatsova et al for MS analysis of vitamin samples in an EWOD platform that was interfaced with capillary electrophoretic (CE) separating chambers ( Fig.…”
Section: Applications Of Ewodmentioning
confidence: 99%
See 1 more Smart Citation
“…Magnetic silica beads were used as the adsorbent and immobilized in the channel by magnets. In addition to continuous flow mode, Lee and co-workers developed a digital microfluidic device for controlling droplet movement to realize magnetic beads-based SPE . Qian’s group introduced SPME particles into the microchannel and in situ polymerization of them .…”
Section: Size Reduction Accelerationmentioning
confidence: 99%