2018
DOI: 10.1016/j.hrthm.2017.10.022
|View full text |Cite
|
Sign up to set email alerts
|

Safety of magnetic resonance imaging in patients with legacy pacemakers and defibrillators and abandoned leads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

3
51
0
2

Year Published

2018
2018
2021
2021

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 75 publications
(56 citation statements)
references
References 22 publications
3
51
0
2
Order By: Relevance
“…Similarly, no adverse events were seen with MRI in a cohort that included nine patients with epicardial leads, and in nine congenital heart disease patients with epicardial leads . Recently, a larger cohort of 80 patients with abandoned leads was reported with no adverse effects and no significant changes in troponin values . The 2017 HRS consensus statement on MR imaging makes no recommendations for MR scanning for this patient population.…”
Section: Discussionmentioning
confidence: 99%
“…Similarly, no adverse events were seen with MRI in a cohort that included nine patients with epicardial leads, and in nine congenital heart disease patients with epicardial leads . Recently, a larger cohort of 80 patients with abandoned leads was reported with no adverse effects and no significant changes in troponin values . The 2017 HRS consensus statement on MR imaging makes no recommendations for MR scanning for this patient population.…”
Section: Discussionmentioning
confidence: 99%
“…The presence of an epicardial or abandoned lead may be an exclusion at a particular institution, but this type of patient is not addressed by current recommendations. There is a growing understanding of the risks and risk mitigation in these scenarios, so patients are not systematically excluded [31]. Overly rigid selection protocols may therefore cause patients more harm (from not scanning) than good.…”
Section: Protocols For Mri In Patients With Ciedsmentioning
confidence: 99%
“…Three posters at HRS 2017 addressed the use of MRI in patients with devices and abandoned leads. [13][14][15] Across all three studies, there were 92 patients with 117 MRI scans included, with all showing that there was no clinical or electrical evidence of any CIED dysfunction, and no occurrence of arrhythmia or pain during the scan. These data show significant promise, and we look forward to reading these completed manuscripts to see details on the inclusion and exclusion criteria.…”
Section: Poster Presentationsmentioning
confidence: 99%