2013
DOI: 10.1161/circulationaha.113.003042
|View full text |Cite
|
Sign up to set email alerts
|

Safety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter Defibrillator

Abstract: F irst introduced to clinical practice in 1980,1 the implantable cardioverter-defibrillator (ICD) improves survival in patients at high risk for sudden cardiac death. [2][3][4][5] Randomized, multicenter studies have shown a relative risk reduction in total mortality of up to 54% and an arrhythmic mortality reduction of 50% to 70%. Offsetting this mortality benefit, however, are significant acute and chronic morbidities associated with the use of transvenous leads.6-9 Procedure-related transvenous lead complic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

16
395
3
22

Year Published

2015
2015
2020
2020

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 506 publications
(452 citation statements)
references
References 32 publications
16
395
3
22
Order By: Relevance
“…The minimum CL for SVT-VT discrimination should be set to prevent clinically significant delays in the detection of hemodynamically unstable VT. PREPARE, EMPIRIC, and MADIT-RIT all support the safety of empirical programming at 200 bpm [96,101,134]. In MADIT-II, approximately 50% of SVT episodes were faster than 170 bpm, and a few were as fast as 250 bpm [82] In INTRINSIC RV, SVT comprised 19% of episodes, with rates between 200 and 250 bpm [135].…”
Section: Svt Limitmentioning
confidence: 79%
See 1 more Smart Citation
“…The minimum CL for SVT-VT discrimination should be set to prevent clinically significant delays in the detection of hemodynamically unstable VT. PREPARE, EMPIRIC, and MADIT-RIT all support the safety of empirical programming at 200 bpm [96,101,134]. In MADIT-II, approximately 50% of SVT episodes were faster than 170 bpm, and a few were as fast as 250 bpm [82] In INTRINSIC RV, SVT comprised 19% of episodes, with rates between 200 and 250 bpm [135].…”
Section: Svt Limitmentioning
confidence: 79%
“…In the single-zone configuration, shocks are delivered for detected heart rates above the programmed rate threshold: the "shock zone" [134]. In the dual-zone configuration, arrhythmia discrimination algorithms are active from the lower rate: the "conditional shock zone."…”
Section: The Subcutaneous Defibrillator (S-icd)mentioning
confidence: 99%
“…In contrast to the development of transvenous ICDs 20 to 30 years ago, step‐down defibrillation threshold (DFT) testing was rarely performed. In the largest S‐ICD registry to date, only 10 of 450 patients had any testing done at <65 J 6, 7…”
mentioning
confidence: 99%
“…Of the 321 subjects of the IDE trial who underwent attempted S‐ICD implantation, 7 (2.2%) did not receive the device as a result of incomplete or unsuccessful acute VF conversion testing 5. In contrast, we did not observe screening failures before implantation, despite varying ECG morphologies of the included patients (eg, ST‐segment elevation in Brugada patients, QRS splitting and T‐wave inversions in hypertrophic cardiomyopathy patients).…”
Section: Discussionmentioning
confidence: 71%