The IMT improves functional capacity and balance, respiratory and peripheral muscle strength; decreases depression and dyspnea perception in patients with heart failure. IMT should be included effectively in pulmonary rehabilitation programs.
The short- as well as the long-term prevalence and recurrence of LTAs in TTS patients is high. The long-term mortality rates were similar to the TTS patients presenting without any LTAs. LTAs in TTS could be triggered by a concomitant atrial fibrillation.
IntroductionFever can increase the susceptibility to supraventricular and ventricular arrhythmias, in which sodium channel dysfunction has been implicated. Whether fever influences the efficacy of sodium channel blocking drugs is unknown. The current study was designed to investigate the temperature dependent effects of distinct sodium channel blocking drugs on the sodium currents in human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs).Methods and ResultshiPSC-CMs were generated from human skin fibroblasts of a healthy donor. The peak and late sodium currents (INa), steady-state activation, inactivation and recovery from inactivation of INa in hiPSC-CMs were analyzed using the whole-cell patch clamp technique. The effects of different concentrations of the antiarrhythmic drugs flecainide, lidocaine, ajmaline and the antianginal drug ranolazine on INa were tested at 36°C and 40°C. Increasing the temperature of the bath solution from 36°C to 40°C enhanced the inhibition of peak INa but reduced the inhibition of late INa by flecainide and lidocaine. By contrast, increasing the temperature reduced the effect of ajmaline and ranolazine on the peak INa but not late INa. None of the tested drugs showed temperature-dependent effects on the steady-state activation and inactivation as well as on the recovery from inactivation of INa in hiPSC-CMs.ConclusionsTemperature variation from the physiological to the febrile range apparently influences the effects of sodium channel blockers on the sodium currents. This may influence their antiarrhythmic efficacy in patients suffering from fever.
Brugada syndrome patients with an SCN5A mutation reveal distinct changes in RV volumes and function when compared with those without an SCN5A mutation. Furthermore, mutation-positive patients have a higher likelihood of a spontaneous type 1 BrS-ECG, which is associated with a higher incidence of clinical events. Cardiovascular magnetic resonance may provide additional insight to distinguish between SCN5A mutation-positive and -negative BrS patients.
BackgroundThe wearable cardioverter-defibrillator (WCD) has emerged as a valuable tool to temporarily protect patients at risk for sudden cardiac death (SCD). The aim of this study was to determine the value of the WCD for therapy optimization of heart failure patients.MethodsOne hundred five consecutive patients that received WCD between 4/2012 and 9/2016 were included in the study. All patients were followed for clinical outcome and echocardiographic parameters during WCD therapy and had continued follow-up after WCD therapy, irrespective of subsequent implantable cardioverter-defibrillator (ICD) implantation.ResultsThe most common indication for WCD were newly diagnosed ischemic (ICM) or non-ischemic cardiomyopathy (NICM) with left ventricular ejection fraction (LVEF) ≤35%. Mean WCD wear time was 68.8 ± 50.4 days with a mean daily use of 21.5 ± 3.5 h. Five patients (4.8%) received a total of five appropriate WCD shocks.During WCD wear, patients with ICM and NICM showed significant improvement in LVEF, reducing the proportion of patients with a need for primary preventive ICD implantation to 54.8% (ICM) and 48.8% (NICM). An ICD was finally implanted in 51.4% of the study patients (24 trans-venous ICDs, 30 subcutaneous ICDs).After discontinuation of WCD therapy, all patients were followed for a mean of 18.6 ± 12.3 months. 5.6% of patients with implanted ICDs received appropriate therapies. No patient with subcutaneous ICD needed change to a trans-venous device. None of the patients without an implanted ICD suffered from ventricular tachyarrhythmias and no patient died suddenly.In patients with NICM a significant LVEF improvement was observed during long-term follow-up (from 34.8 ± 11.1% to 41.0 ± 10.2%).ConclusionsWCD therapy successfully bridged all patients to either LVEF recovery or ICD implantation. Following WCD, ICD implantation could be avoided in almost half of the patients. In selected patients, prolongation of WCD therapy beyond 3 months might further prevent unnecessary ICD implantation. The WCD as an external monitoring system contributed important information to optimize device selection in patients that needed ICD implantation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.