2021
DOI: 10.1055/s-0041-1723065
|View full text |Cite
|
Sign up to set email alerts
|

Safety and Effectiveness of Additional Apical Preparation using a Rotary Heat-treated Nickel–Titanium file with Larger Diameter and Minimum Taper in Retreatment of Curved Root Canals

Abstract: Objective The aim of this study was to investigate the effect of additional apical preparation using the ProDesign Logic (PDL) 50/.01 rotary heat-treated nickel–titanium (NiTi) file with a larger diameter and minimal taper for retreatment of curved root canals. Materials and Methods Mesial curved root canals of 12 mandibular molars were prepared using PDL 25/.06 and filled using the continuous wave of condensation technique and AH Plus sealer. After retreatment using ProDesign S (PDS) 25/.08, PDL 25/.06 and PD… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
9
0
3

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(13 citation statements)
references
References 37 publications
1
9
0
3
Order By: Relevance
“…Roggendorf et al also documented in their research, that enlarging canals by up to two sizes beyond the preretreatment dimension helped reduce the residual sealer amount. 18,19 In this study, further apical preparation was conducted using the ProTaper (F3 file). Following the initial retreatment procedure with ProTaper retreatment, the quantity of RFM was comparable among the groups, which is very likely due to the similar adhesive characteristics of the sealers.…”
Section: Discussionmentioning
confidence: 99%
“…Roggendorf et al also documented in their research, that enlarging canals by up to two sizes beyond the preretreatment dimension helped reduce the residual sealer amount. 18,19 In this study, further apical preparation was conducted using the ProTaper (F3 file). Following the initial retreatment procedure with ProTaper retreatment, the quantity of RFM was comparable among the groups, which is very likely due to the similar adhesive characteristics of the sealers.…”
Section: Discussionmentioning
confidence: 99%
“…28 In agreement, previous investigation showed the safety of this file during retreatments of curved canals since PDL 50/0.01 has high flexural strength and provides apical enlargement with no root canal transportation. 12 Curved root canals may favor the occurrence of apical transportation, zipping or crack formation during preparation, and retreatment procedures, with impair the treatment outcome. 2,29 Mesial root canals of mandibular molars with a curvature of 25 and 35 degrees were used in the present study representing moderate root curvatures.…”
Section: Discussionmentioning
confidence: 99%
“… 3 Thus, additional apical preparation using nickel–titanium (NiTi) instruments with large diameter and small taper has been proposed to improve the removal of remaining material in curved canals. 11 12 ProDesign Logic 50/0.01 (Easy Equipamentos Odontológicas, Belo Horizonte, Minas Gerais, Brazil) has diameter of 50 and a small taper of 0.01. This instrument significantly reduces the amount of filling material in the apical third of maxillary lateral incisors 11 and curved canals of mandibular molars.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…20 Any instrument that is designed to minimize the contact area that exists between the instrument and the root dentinal walls is sure to decrease the vertical load on it. 21 This could explain the low fracture incidence with Kedo-S Square file system, as the diameter of the file is 0.28 mm with a dual cross-sectional area (triangular cross-section at apical region and teardrop cross-section at coronal region) and has variably variable taper.…”
Section: Discussionmentioning
confidence: 99%