RP‐LC×RP‐LC analysis of a tryptic digest using a combination of totally porous and partially porous stationary phases

Abstract: Different chromatographic separation modes have been combined, in off-line and on-line approaches, attempting to achieve enhanced separation power for the analysis of complex proteome samples. Among these, the use of RP-LC x RP-LC brings in the added advantages of high peak capacity in both dimensions, capability of full automation, and the likelihood of direct hyphenation to MS. In this contribution, we achieved enhanced resolution in the first dimension, by serially coupling Bio wide pore C18 columns at basi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
19
0
1

Year Published

2011
2011
2017
2017

Publication Types

Select...
6
3

Relationship

4
5

Authors

Journals

citations
Cited by 39 publications
(21 citation statements)
references
References 76 publications
(69 reference statements)
1
19
0
1
Order By: Relevance
“…Therefore, in this work, for the 1 D separations, a 15 cm-long, silica HILIC column, built on the Fused core technology, was used. Such a stationary phase was successfully employed in previous researches, either in one-dimensional or multidimensional LC × LC set-ups [8,[25][26][27][28][29][30][31]. Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, in this work, for the 1 D separations, a 15 cm-long, silica HILIC column, built on the Fused core technology, was used. Such a stationary phase was successfully employed in previous researches, either in one-dimensional or multidimensional LC × LC set-ups [8,[25][26][27][28][29][30][31]. Fig.…”
Section: Resultsmentioning
confidence: 99%
“…In LCxLC there is an absolute need for maximally different selectivities in the two dimensions to produce the highest effective peak capacity. The most direct approach to achieving this is to use radically different modes of separation as discussed above; nonetheless, we and others have used RPLC in both dimensions [26, 43–45] but do so using pairs of reversed phases with radically different selectivity [46,47] or different mobile phase [48,49]. Here, we explore the possibility of changing selectivity by applying different pHs in the mobile phase of the first dimension.…”
Section: Resultsmentioning
confidence: 99%
“…In particular, the monolithic column employed in the D2 was replaced by a partially porous column (fused core technology) [23][24][25]. In this regard, recent studies have demonstrated the possibility to use these columns in the D2 of comprehensive LC systems in order to obtain very fast D2 gradient elution separations [19,20,26].…”
Section: Analysis Of a Borage Oil Sample By 2-d Ag 1 -Lc â Rp-lcmentioning