2014
DOI: 10.1016/j.arabjc.2012.07.010
|View full text |Cite
|
Sign up to set email alerts
|

RP-HPLC-DAD method for the determination of phenylepherine, paracetamol, caffeine and chlorpheniramine in bulk and marketed formulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
23
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 37 publications
(24 citation statements)
references
References 7 publications
1
23
0
Order By: Relevance
“…In order to strengthen the supervision and management of food hygiene, it is imperative for the determination of caffeine to develop a standard method. In addition to taste sensor technique (Chen et al ., ), there are lots of traditional methods for caffeine detection including spectrophotometry (Kalra et al ., ), gas chromatography‐mass spectrometry (GC‐MS) (Wu & Tseng, ), liquid chromatography‐mass spectrometry (LC‐MS) and high‐performance liquid chromatography coupled with photodiode array detector (HPLC‐DAD) (Tfouni et al ., ; Dewani et al ., ). However, these methods are not only laborious and time‐consuming but also need a large number of organic reagents and expensive instruments.…”
Section: Introductionmentioning
confidence: 97%
“…In order to strengthen the supervision and management of food hygiene, it is imperative for the determination of caffeine to develop a standard method. In addition to taste sensor technique (Chen et al ., ), there are lots of traditional methods for caffeine detection including spectrophotometry (Kalra et al ., ), gas chromatography‐mass spectrometry (GC‐MS) (Wu & Tseng, ), liquid chromatography‐mass spectrometry (LC‐MS) and high‐performance liquid chromatography coupled with photodiode array detector (HPLC‐DAD) (Tfouni et al ., ; Dewani et al ., ). However, these methods are not only laborious and time‐consuming but also need a large number of organic reagents and expensive instruments.…”
Section: Introductionmentioning
confidence: 97%
“…The development of the method was based on the experience obtained from the HPLC method previously developed for the analysis of mixture of analytes comprising phenylephrine, paracetamol, caffeine and chlorpheniramine maleate (Dewani et.al 2012) (25) by authors. Experiments previously suggest use of C-18 stationary phases of (150 mm × 4.5mm i.d., particle size 5 μm) hence for the study an reverse phase Phenomenex Kinetex-C18 column was utilized.…”
Section: Methods Development and Optimization Of Chromatographic Condimentioning
confidence: 99%
“…Precision was determined by repeatability, inter day and intraday reproducibility experiments 13,14 ( Table 4). A standard solution containing drugs were injected six times.…”
Section: Precisionmentioning
confidence: 99%