2016
DOI: 10.1587/transele.e99.c.339
|View full text |Cite
|
Sign up to set email alerts
|

Room-Temperature Gold-Gold Bonding Method Based on Argon and Hydrogen Gas Mixture Atmospheric-Pressure Plasma Treatment for Optoelectronic Device Integration

Abstract: SUMMARYLow-temperature bonding methods of optoelectronic chips, such as laser diodes (LD) and photodiode (PD) chips, have been the focus of much interest to develop highly functional and compact optoelectronic devices, such as microsensors and communication modules. In this paper, room-temperature bonding of the optoelectronic chips with Au thin film to coined Au stud bumps with smooth surfaces (R a : 1.3 nm) using argon and hydrogen gas mixture atmospheric-pressure plasma was demonstrated in ambient air. The … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 23 publications
(10 citation statements)
references
References 19 publications
0
10
0
Order By: Relevance
“…It is to be noted that no OH radical related peaks were observed in the emission spectra. It is known that the OH related peak appears at a wavelength of 310 nm [21] . Hence, this peak is probably hidden by the broadened continuous spectra as shown in Fig.…”
Section: Discussionmentioning
confidence: 99%
“…It is to be noted that no OH radical related peaks were observed in the emission spectra. It is known that the OH related peak appears at a wavelength of 310 nm [21] . Hence, this peak is probably hidden by the broadened continuous spectra as shown in Fig.…”
Section: Discussionmentioning
confidence: 99%
“…To achieve the best bond interface, the Ti/Au was deposited as thin as possible with a sputter. Two substrates were bonded at low temperature after Ar+H2 plasma surface pretreatment before bonding [3]. Lower Au to Au bonding temperatures are advantageous because extreme temperature differences between cryogenic operating temperatures and bonding temperatures can induce significant stresses.…”
Section: Fabricationmentioning
confidence: 99%
“…Au-Au surface activated bonding (SAB) [17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35] is a promising technique for low-temperature bonding. In Au-Au SAB, the Au surfaces are activated by plasma treatment and then brought into contact at low temperature (<150 • C).…”
Section: Introductionmentioning
confidence: 99%