2019
DOI: 10.1016/j.ab.2019.04.016
|View full text |Cite
|
Sign up to set email alerts
|

Rolling circle amplification and graphene-based sensor-on-a-chip for sensitive detection of serum circulating miRNAs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 25 publications
(15 citation statements)
references
References 29 publications
0
15
0
Order By: Relevance
“…This result can be used to explain why the optimum concentrations of GRA and DNA probes must be obtained before the actual experiment can be performed in many previous studies. 27,37 The presence of multiple miR-29a chains covering a GRA nanosheet allows more miR−DNA interactions. Both DNA1 and DNA2 in 4R4D form a permanent interaction network with miR-29a, but DNA2 shows tighter binding (Figure 4B).…”
Section: ■ Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This result can be used to explain why the optimum concentrations of GRA and DNA probes must be obtained before the actual experiment can be performed in many previous studies. 27,37 The presence of multiple miR-29a chains covering a GRA nanosheet allows more miR−DNA interactions. Both DNA1 and DNA2 in 4R4D form a permanent interaction network with miR-29a, but DNA2 shows tighter binding (Figure 4B).…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Therefore, in this work, the addition of complementary DNA probes into the miR–GQD solution is studied to explore the possibility of detecting GRA-adhered miR-29a by probes. DNA probes in this study were successfully employed to detect miR-29a in a previous experimental work (Figure A). The folded DNA is used here to mimic the behavior of native DNA in a miR–GQD solution.…”
Section: Introductionmentioning
confidence: 99%
“…Two fluorescence-labelled circular ssDNA tags were added to the system for the detection of miR-29a and miR-144, which are particularly important since they are highly expressed in some patients with cancer. The resulting platform showed high sensitivity and selectivity, with a LOD of 0.05 pmol, and was able to detect multiplex miRNAs from both human serum and HeLa cells [ 33 ].…”
Section: Outcomementioning
confidence: 99%
“…As shown in Table S2 (ESI †), the detection efficiency, detection range, LOD, and other performance metrics displayed in our approach were better than others. [18][19][20][21][22][23][24][25][26][27] Without a doubt, this ultrasensitive detection threshold can be ascribed to following reasons: (i) the adoption of the self-quenching fluorescence probes makes detective signal-tobackground ratio greatly improved. Thus, the targets at lower concentrations can be easily detected; (ii) only two kinds of probes are employed in the system, the occurrence of non-specific amplification is avoided, and the exponential growth of products and signals is also guaranteed.…”
Section: Please Do Not Adjust Marginsmentioning
confidence: 99%