2005
DOI: 10.1136/adc.2004.062745
|View full text |Cite
|
Sign up to set email alerts
|

Role of cerebral function monitoring in the newborn

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
62
1
3

Year Published

2007
2007
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 104 publications
(67 citation statements)
references
References 48 publications
1
62
1
3
Order By: Relevance
“…The aEEG signal scoring method employed in this study was based on the techniques of de Vries et al (10). In other studies, the weights of 1 and 2, given to continuous low-voltage and burst suppression activity, respectively, are switched, since seizure activity is particularly destructive and is of the upmost importance for treatment.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The aEEG signal scoring method employed in this study was based on the techniques of de Vries et al (10). In other studies, the weights of 1 and 2, given to continuous low-voltage and burst suppression activity, respectively, are switched, since seizure activity is particularly destructive and is of the upmost importance for treatment.…”
Section: Discussionmentioning
confidence: 99%
“…The background pattern was classified as either continuous or discontinuous, and the presence of seizure activity or burst-suppression pattern was noted. A summary of the scoring method is presented in Table 1 based on the analysis of de Vries et al (10). The aEEG data from each experiment were scored in 10-min intervals by an analyst blinded to the duration of hypoxia-ischemia.…”
Section: Methodsmentioning
confidence: 99%
“…Both the background pattern and voltage criteria were evaluated, and care was taken to recognize interference, which can cause significant upward drift of the baseline. 8 The aEEG traces were classified as having moderately abnormal amplitude, with the lower margin of the trace <5 mV and upper margin >10 mV, or severely depressed amplitude, with the upper margin of the trace <10 mV. In addition, each aEEG was classified according to the presence or absence of seizures.…”
Section: Methodsmentioning
confidence: 99%
“…Dianjurkan kejang neonatus pertama kali dikonfirmasi dengan pemeriksaan EEG konvensional, selanjutnya CFM dipakai untuk monitor jangka panjang. 15,16 Pemeriksaan EEG dan CFM juga dipakai untuk melihat respon terapi antikonvulsan dengan berkurangnya aktifitas epileptiform, serta menentukan lama terapi dan prognosis.…”
Section: Evaluasi Diagnostikunclassified