2016
DOI: 10.1109/taslp.2016.2593803
|View full text |Cite
|
Sign up to set email alerts
|

Robust Room Impulse Response Measurement Using Perfect Sequences for Legendre Nonlinear Filters

Abstract: The paper proposes a novel approach for measuring the room impulse response that is robust toward the nonlinearities affecting the power amplifier or the loudspeaker. The approach is implemented by modeling the acoustic path as a Legendre nonlinear filter and by measuring the first-order kernel using perfect periodic sequences and the cross-correlation method. Perfect sequences for Legendre filters are periodic sequences that guarantee the orthogonality of the Legendre basis functions over a period. They ensur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 22 publications
0
15
0
Order By: Relevance
“…There are multiple methods for gathering a RIR: Impulse, Chirp, Linear/Logarithmic sweep, Maximum-Length Signal (MLS) and Inverse Repeated Signal (IRS). These have been compared and tested in many papers [6], [7] and [8]. However, the testing parameters from these works have never explored the situation where the receiver, source or environment is moving.…”
Section: A Room Impulse Responsementioning
confidence: 99%
“…There are multiple methods for gathering a RIR: Impulse, Chirp, Linear/Logarithmic sweep, Maximum-Length Signal (MLS) and Inverse Repeated Signal (IRS). These have been compared and tested in many papers [6], [7] and [8]. However, the testing parameters from these works have never explored the situation where the receiver, source or environment is moving.…”
Section: A Room Impulse Responsementioning
confidence: 99%
“…In [35,36], a novel approach for RIR measurement robust towards nonlinearities with memory was proposed. In this approach, the entire measurement system, composed of the power amplifier, the loudspeaker, the acoustic path, and the microphone, is directly modeled as a Legendre nonlinear (LN) filter.…”
Section: Introductionmentioning
confidence: 99%
“…Indeed, with a uniform distribution 42% of the samples have magnitude larger than the standard deviation, while with a Gaussian distribution the value reduces to 32% of the samples. In this paper, we extend the approach of [36] and consider the robust RIR measurement using PPSs for WN filters. This measurement was first proposed by the authors in the conference paper [39] and it is fully detailed in the current manuscript.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations