2017
DOI: 10.1109/tpel.2016.2626290
|View full text |Cite
|
Sign up to set email alerts
|

Robust Active Damping Methods for LCL Filter-Based Grid-Connected Converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
48
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 126 publications
(51 citation statements)
references
References 29 publications
2
48
0
1
Order By: Relevance
“…In some applications, it is possible to control the inner loop with a simple proportional regulator for the sole purpose of increasing the high-frequency loop gain, while steady-state errors in grid-current control are handled by the outer grid current loop [79]. The outer loop regulator varies from application to application; the literature reports the use of the simple PI control [79], [80], the PR [37], [40], [78], the PR + odd harmonic repetitive control (OHRC) [81] or the quasi-proportional-resonant fuzzy control [82].…”
Section: B Double-loop Control Structuresmentioning
confidence: 99%
“…In some applications, it is possible to control the inner loop with a simple proportional regulator for the sole purpose of increasing the high-frequency loop gain, while steady-state errors in grid-current control are handled by the outer grid current loop [79]. The outer loop regulator varies from application to application; the literature reports the use of the simple PI control [79], [80], the PR [37], [40], [78], the PR + odd harmonic repetitive control (OHRC) [81] or the quasi-proportional-resonant fuzzy control [82].…”
Section: B Double-loop Control Structuresmentioning
confidence: 99%
“…One is to add additional compensation network in the inverter or hardware equipment outside the inverter after the instability phenomenon occurs in the power plant [11][12][13][14][15][16][17][18][19][20][21][22]. Additionally, the other is the optimization design by taking grid impedance into account before the inverter is produced [23][24][25][26][27][28][29][30].…”
Section: Introductionmentioning
confidence: 99%
“…Thus, more considerations should be paid to wide variation of the ratio between the sampling frequency and the filter resonant frequency [14]. In prior arts, the issue regarding unknown grid impedance was further alleviated by using some improved damping methods, such as robust or hybrid damping schemes [15][16][17].…”
Section: Introductionmentioning
confidence: 99%