2019
DOI: 10.3390/en12132637
|View full text |Cite
|
Sign up to set email alerts
|

An Integrated Design Approach for LCL-Type Inverter to Improve Its Adaptation in Weak Grid

Abstract: To improve the robustness of grid-connected inverter against grid impedance in a weak grid an integrated design method of LCL-filter parameters and controller parameters is proposed. In the method the inherent relation of LCL-filter parameters and controller parameters is taken into consideration to realize their optimized match. A parameter normalization scheme is also developed to facilitate the system stability and robustness analysis. Based on the method all normalization parameters can be designed succinc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 36 publications
(84 reference statements)
0
6
0
Order By: Relevance
“…Moreover, the LCL filter has a dominant switching harmonic of 0.57%, which is expected since the LCL does not have a trap in the dominant switching frequency. On the other hand, the LLCL filter performs better in the dominant switching fre-FIGURE 9 Simulation results of the grid-tied inverter with LLCL filter (a) Simulation waveforms, (b) i g spectrum quency than the LCL filter but has the largest size among all the selected filters. The total volume of cores for the filters' inductors is calculated based on the area-product method [70].…”
Section: Simulation Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Moreover, the LCL filter has a dominant switching harmonic of 0.57%, which is expected since the LCL does not have a trap in the dominant switching frequency. On the other hand, the LLCL filter performs better in the dominant switching fre-FIGURE 9 Simulation results of the grid-tied inverter with LLCL filter (a) Simulation waveforms, (b) i g spectrum quency than the LCL filter but has the largest size among all the selected filters. The total volume of cores for the filters' inductors is calculated based on the area-product method [70].…”
Section: Simulation Resultsmentioning
confidence: 99%
“…It is worth mentioning that M ig and M gi are equal and thus can be referred to as M ig . Based on (8) and (9), it is noted that the two inductors are coupling with each other. According to (8), V i and V g can finally be described as:…”
Section: Expression Of Integrated Llcl Filter Inductorsmentioning
confidence: 99%
See 2 more Smart Citations
“…Typically, the traction transformer (TT) leakage inductance has been used as the inductance of the grid-side converter for maximizing the utilization of the iron core while also meeting the criteria for compact size and low weight in HST equipment [11]. In [12][13][14][15][16][17][18][19][20][21][22][23], various configurations of LCLmodified filters have been presented. Many of these filters have additional LC traps, resonant tanks in series or parallel, resonated at the switching frequencies and their multiples, which allows bypassing or blocking specified harmonics via those traps.…”
Section: Introductionmentioning
confidence: 99%