2022
DOI: 10.1049/pel2.12415
|View full text |Cite
|
Sign up to set email alerts
|

Enhancing power quality of high‐speed railway traction converters by fully integrated T‐LCL filter

Abstract: Modulating the traction converters produces current harmonics at the switching frequencies and their multiples. These harmonics should be minimized to meet the network specifications. The LC‐trapped filters, tuned to these frequencies, can easily meet this requirement, but the existing applicable trap filters have not been studied with the traditional traction system topologies. Thus, this paper presents a trapped LCL filter with an LC resonator on the converter side, called a fully integrated T‐LCL filter, fo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(13 citation statements)
references
References 70 publications
0
13
0
Order By: Relevance
“…To address the problems of difficulties, complexities, and expense, HIL has been used to assess power inverters [71], [73], [75]- [78]. The evaluation by HIL validation of the network-tied converter with passive filters is made more desirable, according to the results in [8], [32], [36], [43], [70], [75], [76].…”
Section: Hil Experimental Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…To address the problems of difficulties, complexities, and expense, HIL has been used to assess power inverters [71], [73], [75]- [78]. The evaluation by HIL validation of the network-tied converter with passive filters is made more desirable, according to the results in [8], [32], [36], [43], [70], [75], [76].…”
Section: Hil Experimental Resultsmentioning
confidence: 99%
“…After completing the design processes, all of the integrated DTLCL, discrete SPRLCL, LCL, and L filters parameters are provided in Table 1. In addition, the same controller implemented in [36], [43], [45], [48], [53], [69], [70] may be used for the traction inverter with the integrated DTLCL filter, which is not discussed here. Section 4 will present the verification results for the proposed filter's design feasibility.…”
Section: Designing and Modeling Of Magnetic Integrated Dtlcl Filtermentioning
confidence: 99%
“…In [7][8][9] the magnetic structures have several inductor windings and transformer windings integrated into a core, the volume of the magnetic devices reduces significantly. In [10,11] the fully integrated T-LCL filters are proposed, the filters are the trapped LCL filter with the LC resonator on the converter side. In [12] the design technique of magnetically inte-grated LLCL filters for grid-tied is proposed.…”
Section: Introductionmentioning
confidence: 99%
“…In [12] the design technique of magnetically inte-grated LLCL filters for grid-tied is proposed. In [10][11][12] the converters reduce the size by winding many coils through magnetic integration, which is the existing most extensive methods for power density increasing. However, these methods only fit for the high-frequency PWM converters.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, developing controllers suitable for LCL type single-phase converters faces huge challenges. Traditional PI linear controllers are usually used for gridside converters of high-speed railways [12,13]. However, the process of adjusting the PI parameters in the voltage or current control loop can be a problem, as incorrect settings may result in undesired low-frequency oscillations in traction networks.…”
mentioning