2019
DOI: 10.1117/1.jbo.24.9.096005
|View full text |Cite
|
Sign up to set email alerts
|

Ring-array photoacoustic tomography for imaging human finger vasculature

Abstract: For early diagnosis of rheumatoid arthritis (RA), it is important to visualize its potential marker, vascularization in the synovial membrane of the finger joints. Photoacoustic (PA) imaging, which can image blood vessels at high contrast and resolution, is expected to be a potential modality for earlier diagnosis of RA. In previous studies of PA finger imaging, different acoustic schemes, such as linear-shaped arrays, have been utilized, but these have limited detection views, rendering inaccurate reconstruct… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
24
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
3
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 33 publications
(26 citation statements)
references
References 38 publications
0
24
0
Order By: Relevance
“…By using transducer arrays, PACT can capture PA signals in different views for each single laser pulse with a cost of detection bandwidth (single element transducer: up to hundreds of MHz; transducer array: tens of MHz), leading to a higher temporal resolution (10−200 Hz, or frames per second) and a lower spatial resolution. Full-ring-array-based PACT can receive PA signals over a view of 360° to eliminate artifacts and improve SNR, which has been extensively applied in detecting breast cancerous lesions [ 35 , 53 ], evaluating human joint diseases [ 52 , 54 , 55 ], and visualizing vasculatures in human extremities [ 56 ]. However, due to the configuration of full-ring transducer arrays, it is hard to design handheld or semi-handheld devices.…”
Section: Progress In Handheld and Semi-handheld Pactmentioning
confidence: 99%
“…By using transducer arrays, PACT can capture PA signals in different views for each single laser pulse with a cost of detection bandwidth (single element transducer: up to hundreds of MHz; transducer array: tens of MHz), leading to a higher temporal resolution (10−200 Hz, or frames per second) and a lower spatial resolution. Full-ring-array-based PACT can receive PA signals over a view of 360° to eliminate artifacts and improve SNR, which has been extensively applied in detecting breast cancerous lesions [ 35 , 53 ], evaluating human joint diseases [ 52 , 54 , 55 ], and visualizing vasculatures in human extremities [ 56 ]. However, due to the configuration of full-ring transducer arrays, it is hard to design handheld or semi-handheld devices.…”
Section: Progress In Handheld and Semi-handheld Pactmentioning
confidence: 99%
“…7 Initial results have shown promise of using PA for RA imaging. [8][9][10][11] In this work, we have used an LED-based hand-held PA imaging system for pre-clinical RA imaging on rodent models. We have developed a multicenter 3Rs (Replace, Refine and Reduce) strategy to refine and reduce animal use in RA-related research.…”
Section: Introductionmentioning
confidence: 99%
“…Raster scanning of the confocally aligned optical illumination and acoustic detection gives 3-dimensional volumetric image of the target sample [17]. On the other hand, in PAT the sample is homogeneously illuminated by laser pulses and single or multiple USTs are used to acquire photoacoustic (PA) waves from different angles around the sample [18,19]. Reconstruction algorithms are used to process the collected PA waves and form cross-sectional images of the target.…”
Section: Introductionmentioning
confidence: 99%