Rifampicin-loaded electrospun polycaprolactone membranes: Characterization of stability, antibacterial effects and urotheliocytes proliferation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 84 publications
1
3
0
Order By: Relevance
“…The highly porous structure, characterized by open and well-interconnected pores and thin struts within the cells, is probably responsible for this high degradation degree and rate. A further explanation, when comparing the current results with tests carried out in other media, can be ascribed to the better wettability of PCL by DMEM than other mediums like physiological buffer solution (PBS), as determined by Musciacchio et al (2022) [36].…”
Section: Pcl-and Bcp/pcl-based 3d Scaffold Biodegradability Degreesupporting
confidence: 67%
“…The highly porous structure, characterized by open and well-interconnected pores and thin struts within the cells, is probably responsible for this high degradation degree and rate. A further explanation, when comparing the current results with tests carried out in other media, can be ascribed to the better wettability of PCL by DMEM than other mediums like physiological buffer solution (PBS), as determined by Musciacchio et al (2022) [36].…”
Section: Pcl-and Bcp/pcl-based 3d Scaffold Biodegradability Degreesupporting
confidence: 67%
“…The effect of the collector speed on fiber orientation and inner diameters of coaxial electrospun hollow fibers was assessed statistically by firstly determining the distribution of the data set using the Kolmogorov-Smirnov test. 39 The data set was then assessed for homogenous vari- is consistent with the observation of their surface morphology (Figure 2B). For the 1.4 mL/h strip, fiber merging, as shown by crosssectional SEM (Figure 2K), was also similar to that shown by its surface topography (Figure 2E).…”
Section: Discussionmentioning
confidence: 83%
“…The effect of the collector speed on fiber orientation and inner diameters of coaxial electrospun hollow fibers was assessed statistically by firstly determining the distribution of the data set using the Kolmogorov–Smirnov test. 39 The data set was then assessed for homogenous variance using Levene's test. Data sets which fulfilled the Kolmogorov–Smirnov test and Levene's test criteria were assessed using ANOVA with a Tukey post‐test.…”
Section: Methodsmentioning
confidence: 99%
“…The hydrophobic nature of the PCL/Rif membrane allowed for moistening by physiological liquids and cell media, ensuring cell adhesion, proliferation, and prolonged antibacterial activity against urothelial cells and smooth muscle cells, making it suitable for ureteral regeneration. This fibrous membrane stands as a potential ureteral stent for urothelial carcinoma [ 153 ].…”
Section: Application Of Drug-loaded Nanofibers In Cancer Therapymentioning
confidence: 99%