2010
DOI: 10.1134/s0965545x10090099
|View full text |Cite
|
Sign up to set email alerts
|

Rheological properties of solutions of chitosan and its graft copolymer with N-vinylcaprolactam

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
9
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…This reaction was performed under homogeneous conditions using a mixture of solvents at 60 °C. Unfortunately, this reaction is reported to be accompanied by a decrease in the molecular weight of chitosan, probably caused by the cleavage of the glycoside bonds by potassium persulfate [76,77]. In the grafting from technique, the radical chain polymerization of a monomer is triggered by the thermal decomposition of the initiator.…”
Section: Synthesismentioning
confidence: 99%
See 1 more Smart Citation
“…This reaction was performed under homogeneous conditions using a mixture of solvents at 60 °C. Unfortunately, this reaction is reported to be accompanied by a decrease in the molecular weight of chitosan, probably caused by the cleavage of the glycoside bonds by potassium persulfate [76,77]. In the grafting from technique, the radical chain polymerization of a monomer is triggered by the thermal decomposition of the initiator.…”
Section: Synthesismentioning
confidence: 99%
“…These authors suggested that this behaviour is related to the presence of flexible PVCL chain blocks that easily unwind and orient in a flow when increasing the shear rate [77].…”
Section: Propertiesmentioning
confidence: 99%
“…These factors determine the very complicated behavior of chitosan macromolecules in the solution [17][18][19][20][21][22]. This explains partly the discrepancy between certain literature data on the concentration modes and the critical rheological parameters ( C * , C e ) of chitosan solutions and the diffi culty of comparing them.…”
mentioning
confidence: 99%
“…The swelling of samples as a function of CS DD was judged from the d CS /d CT ratio. The behavior with shear flow of the selected samples in H 2 O and acidic solutions was studied on a Rheotest-2 instrument [3].The tests showed that increasing DD resulted in increased swelling of CS samples in H 2 O. The swelling was greater for DD ≥ 90% (Fig.…”
mentioning
confidence: 99%
“…The swelling of samples as a function of CS DD was judged from the d CS /d CT ratio. The behavior with shear flow of the selected samples in H 2 O and acidic solutions was studied on a Rheotest-2 instrument [3].…”
mentioning
confidence: 99%