2014
DOI: 10.1016/j.arth.2013.04.007
|View full text |Cite
|
Sign up to set email alerts
|

Revision of Ceramic Head Fracture After Third Generation Ceramic-on-Ceramic Total Hip Arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
23
0
2

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(29 citation statements)
references
References 12 publications
3
23
0
2
Order By: Relevance
“…A serious complication with ceramic implants is fracture, which may lead to reoperation and to a poor prognosis. One study showed that at a mean follow-up of 5 years after revision due to ceramic head fracture in 24 patients with BIOLOX forte ceramic bearings, 5 patients needed a second revision and 2 of them underwent a third revision ( Koo et al 2014 ). The reported incidence of ceramic component fracture varies from 0.01% to 3.5% ( Ha et al 2007 , D’Antonio and Sutton 2009 , Traina et al 2011 ).…”
Section: Discussionmentioning
confidence: 99%
“…A serious complication with ceramic implants is fracture, which may lead to reoperation and to a poor prognosis. One study showed that at a mean follow-up of 5 years after revision due to ceramic head fracture in 24 patients with BIOLOX forte ceramic bearings, 5 patients needed a second revision and 2 of them underwent a third revision ( Koo et al 2014 ). The reported incidence of ceramic component fracture varies from 0.01% to 3.5% ( Ha et al 2007 , D’Antonio and Sutton 2009 , Traina et al 2011 ).…”
Section: Discussionmentioning
confidence: 99%
“…28,29 However, although uncommon, fracture of ceramic heads is still a concern as it results in a catastrophic complication. 30,31 Future long-term follow-up studies are needed to determine implant survivorship in tall-statured patients with large diameter acetabular cups and femoral heads. This study is not without limitations.…”
Section: Discussionmentioning
confidence: 99%
“…Der Erhalt der Schaftkomponente ist in diesen Fällen auch abhängig vom Erhalt des Konus. Von der Anwendung eines neuen Keramikkopfes bei gebrauchtem Konus ist dringend abzuraten, da minimale Veränderungen des Konus zu einem erhöhten Bruchrisiko des Keramikkopfes führen können [26]. Eine Option sind Keramikköpfe mit Titanadapterhülse, die einen unnötigen Wechsel eines festsitzenden Femurschafts verhindern, wodurch die Operationszeit verkürzt und mögliche perioperative Komplikationen reduziert werden können [15, 48 -50].…”
Section: Conclusion Modern Coc Bearings Show Advantages In Pre-unclassified
“…Eine Option sind Keramikköpfe mit Titanadapterhülse, die einen unnötigen Wechsel eines festsitzenden Femurschafts verhindern, wodurch die Operationszeit verkürzt und mögliche perioperative Komplikationen reduziert werden können [15, 48 -50]. Dabei ist aber die genaue Inspektion des Konus mit haptisch-manueller Prüfung der Oberfläche entscheidend, da nur bei fehlender Konusschädigung ein Titanadapter angewendet werden darf [26,30,51]. Zusätzlich bieten manche Hersteller bereits Instrumente zur intraoperativen Überprüfung der Konusgeometrie an.…”