2017
DOI: 10.1016/j.ejmp.2017.10.013
|View full text |Cite
|
Sign up to set email alerts
|

Review of technologies and procedures of clinical dosimetry for scanned ion beam radiotherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
38
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 35 publications
(41 citation statements)
references
References 205 publications
0
38
0
Order By: Relevance
“…The measurements described in Section 2 are the basis for precise and accurate charged‐particle dosimetry but additional dosimetric information is needed for realistic patient‐specific scenarios and the different dose delivery configurations, above all for the advanced pencil beam scanning technique. Actually, pre‐clinical pencil beam characterization (acceptance and commissioning) and QA procedures require various relative dose measurements as summarized in a recent review on technologies and procedures of clinical dosimetry for scanned ion beam radiotherapy . Commissioning and QA is not only necessary for the beam parameters but also for the equipment itself and an overview of a comprehensive implementation addressing the specific demands of scanned beams is given by Grevillot et al …”
Section: Detectors For Absorbed Dose In Nonreference Conditionsmentioning
confidence: 99%
See 4 more Smart Citations
“…The measurements described in Section 2 are the basis for precise and accurate charged‐particle dosimetry but additional dosimetric information is needed for realistic patient‐specific scenarios and the different dose delivery configurations, above all for the advanced pencil beam scanning technique. Actually, pre‐clinical pencil beam characterization (acceptance and commissioning) and QA procedures require various relative dose measurements as summarized in a recent review on technologies and procedures of clinical dosimetry for scanned ion beam radiotherapy . Commissioning and QA is not only necessary for the beam parameters but also for the equipment itself and an overview of a comprehensive implementation addressing the specific demands of scanned beams is given by Grevillot et al …”
Section: Detectors For Absorbed Dose In Nonreference Conditionsmentioning
confidence: 99%
“…Segmented ICs are also adequate for planar dose checks but for the low spatial resolution (5–10 mm) these dosimeters are not recommended for commissioning and TPS validation while are a good choice for QA tests …”
Section: Detectors For Absorbed Dose In Nonreference Conditionsmentioning
confidence: 99%
See 3 more Smart Citations