Implementation of Sphinx/Lynx as daily QA equipment for scanned proton and carbon ion beams

Abstract: Purpose Reporting on the first implementation of a proton dedicated commercial device (IBA Sphinx/Lynx) for daily Quality Assurance (QA) of scanned proton and carbon ion beams. Methods Daily QA trendlines over more than 3 years for protons and more than 2 years for carbon ions have been acquired. Key daily QA parameters were reviewed, namely the spot size and position, beam range, Bragg peak width, coincidence (between beam and imaging system isocenters), homogeneity an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 18 publications
1
3
0
Order By: Relevance
“…3, 128.4, 153.1, 223.4, and 252.7 MeV with 2 mm spot spacing in both orthogonal directions and a constant spot weighting. The homogeneity of proton spots fields at MedAustron was currently reported by Grevillot et al, 32 showing a variation within a 7 × 4 cm 2 rectangle of 0.9% ± 0.2%. In contrast to the work of Fuchs et al, 25 a set of laterally shifted 10 × 10 cm 2 single-layer quasi mono-energetic irradiation fields was created by employing horizontal shifts in positive x-direction to compensate for the laterally shifted proton beam path in the MF and, thereby, to re-center the irradiation field at the measurement depth at the reference point of the PPIC.…”
Section: Measurement Setupsupporting
confidence: 58%
See 2 more Smart Citations
“…3, 128.4, 153.1, 223.4, and 252.7 MeV with 2 mm spot spacing in both orthogonal directions and a constant spot weighting. The homogeneity of proton spots fields at MedAustron was currently reported by Grevillot et al, 32 showing a variation within a 7 × 4 cm 2 rectangle of 0.9% ± 0.2%. In contrast to the work of Fuchs et al, 25 a set of laterally shifted 10 × 10 cm 2 single-layer quasi mono-energetic irradiation fields was created by employing horizontal shifts in positive x-direction to compensate for the laterally shifted proton beam path in the MF and, thereby, to re-center the irradiation field at the measurement depth at the reference point of the PPIC.…”
Section: Measurement Setupsupporting
confidence: 58%
“…The effect of this correction itself on the determination of kB,M,Q$k_{\vec{B},M,Q}$ is expected to be minimal. Grevillot et al 32 . used the same beamline and observed only minor fluctuations in the proton field homogeneity for a shifted field.…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…18 The reader is further invited to refer to the work of Grevillot et al for details about the measurement equipment and methodology. 23,24 Some of the commissioning measurements were used for TPS and myQA iON beam modeling, others were used for validation. myQA iON commissioning set-ups were prepared in the TPS.…”
Section: Beam Model Commissioningmentioning
confidence: 99%
“…Several studies 23–28 have established daily QA checks and jigs procedures following AAPM TG‐224 recommendations 29 . However, a quantitative evaluation of the performance of the UHDR delivery system remains lacking.…”
Section: Introductionmentioning
confidence: 99%