Abstract: In interventional cardiology, patients may be exposed to high doses to the skin resulting in skin burns following single or multiple procedures. Reviewing and analysing available software (online or offline) may help medical physicists assessing the maximum skin dose to the patient together with the dose distribution during (or after) these procedures. Method and results: Capabilities and accuracy of available software were analysed through an extensive bibliography search and contacts with both vendor and aut… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
22
0
6

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 21 publications
(29 citation statements)
references
References 33 publications
(21 reference statements)
1
22
0
6
Order By: Relevance
“…The different MC-GPU approach used to calculate doses when compared with other software tools now available on the market should be commented on. The approach used by other software packages is the same and consists of the correction of the displayed air kerma given by the system by a set of factors accounting for different phenomena such as table attenuation or backscattering of the photons [5]. MC-GPU calculates mean doses in tissues and the peak doses for different organs as well as other complex analyses, such as cumulative dose volume histograms.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The different MC-GPU approach used to calculate doses when compared with other software tools now available on the market should be commented on. The approach used by other software packages is the same and consists of the correction of the displayed air kerma given by the system by a set of factors accounting for different phenomena such as table attenuation or backscattering of the photons [5]. MC-GPU calculates mean doses in tissues and the peak doses for different organs as well as other complex analyses, such as cumulative dose volume histograms.…”
Section: Discussionmentioning
confidence: 99%
“…Different monitoring software packages have been developed to tackle these limitations and also to fulfil the need for automatic recording and evaluation of patient-relevant data [3]. In particular, due to the risk of skin injuries [4], special attention has been paid to skin dose and several codes claim to be able to estimate it or are even specially designed to assess it [5]. In the vast majority of cases these codes apply mathematical models and the patient is either described in a simplistic way [6,7,8,9] or more complex models are used [10,11].…”
Section: Introductionmentioning
confidence: 99%
“…From these data, a dose distribution can be calculated, represented graphically and the PSD determined. Figure 4 shows a coloured dose map during a cardiological procedure [ 14 ]. Since all geometrical data are based on parameters of the modality, large errors or unusable results arise when the patient's position relative to the table changes.…”
Section: Parameters Of Patient Exposurementioning
confidence: 99%
“…4 Example of a peak skin dose map from cardiology (Dose Tracking Software DTS, Canon Medical Systems). This map together with numerical dose information was generated by a DMS after the procedure [ 14 ] …”
Section: Parameters Of Patient Exposurementioning
confidence: 99%
“…Several software tools have been developed for the skin dose calculation (SDC) in order to provide the peak skin dose (PSD) during or after the procedure [4]. The approach used by most of SDC tools to estimate the PSD is the same and consists of the methodology proposed by Jones and Pasciak [5].…”
Section: Introductionmentioning