2007
DOI: 10.1002/chin.200745274
|View full text |Cite
|
Sign up to set email alerts
|

Review of Procedures Involving Separation and Preconcentration for the Determination of Cadmium Using Spectrometric Techniques

Abstract: Techniques -(FERREIRA, S. L. C.; DE ANDRADE, J. B.; KORN, M. D. G. A.; PEREIRA, M. D. G.; LEMOS, V. A.; DOS SANTOS, W. N. L.; RODRIGUES, F. D. M.; SOUZA, A. S.; FERREIRA, H. S.; DA SILVA, E. G. P.; J. Hazard. Mater. 145 (2007) 3, 358-367; Inst. Chem., Univ. Fed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0
2

Year Published

2008
2008
2016
2016

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 12 publications
(14 citation statements)
references
References 9 publications
(8 reference statements)
0
12
0
2
Order By: Relevance
“…The parameters were as follows: wavelength 217.0 nm, lamp current 75%, injection temperature 30°C. For Cd analyses (Ferreira et al, ) the samples received the same procedure of Pb and were then directly injected into the graphite tube. The wavelength used was 228.3 nm, while all other parameters were the same as for Pb.…”
Section: Methodsmentioning
confidence: 99%
“…The parameters were as follows: wavelength 217.0 nm, lamp current 75%, injection temperature 30°C. For Cd analyses (Ferreira et al, ) the samples received the same procedure of Pb and were then directly injected into the graphite tube. The wavelength used was 228.3 nm, while all other parameters were the same as for Pb.…”
Section: Methodsmentioning
confidence: 99%
“…Even for those highly sensitive techniques, such as graphite furnace atomic absorption spectrometry (GF AAS) and inductively coupled plasma mass spectrometry (ICP-MS), the redox speciation is only possible by implementing a prior sample preconcentration/extraction method for a reliable analysis. Additionally, prior sample treatment based on preconcentration/extraction is also an outstanding tool for removing some interference present in the samples [6].…”
Section: Introductionmentioning
confidence: 99%
“…The separation and preconcentration of metal ions, after formation of their sparingly soluble aqueous complexes based on cloud point extraction (CPE) have been largely employed in analytical chemistry [21]. The cloud point procedure offers convenience and simplicity when compared with LLE modality, including higher extraction and preconcentration factors, lower cost and lower toxicity for both the analyst and the environment.…”
Section: Introductionmentioning
confidence: 99%
“…The cloud point procedure offers convenience and simplicity when compared with LLE modality, including higher extraction and preconcentration factors, lower cost and lower toxicity for both the analyst and the environment. The procedure is based on exploiting the properties of non-ionic or amphoteric surfactants at levels above their critical micellar concentrations (CMC) [21]. Above CMC, a system originally composed of a unique phase is separated into two isotropic phases if some condition such as temperature or pressure is changed or if an appropriate substance is added to the solution [22].…”
Section: Introductionmentioning
confidence: 99%