2012
DOI: 10.1063/1.4759438
|View full text |Cite
|
Sign up to set email alerts
|

Reversible solid-state hydrogen-pump driven by magnetostructural transformation in the prototype system La(Fe,Si)13Hy

Abstract: In magnetocaloric La(Fe,Si)13 alloys, it is known that hydrogen addition shifts the magnetic transition temperature TC near room temperature. By partial hydrogen desorption, TC can be adjusted precisely towards the working temperature of a magnetic cooling device. In this work, we studied the stability of partially desorbed LaFe11.6Si1.4Hy and show that the large volume difference of ferro- and para-magnetic phases drives the system from a single phase to a stable two-phase configuration. The hydrogen concentr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
33
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 48 publications
(34 citation statements)
references
References 32 publications
0
33
1
Order By: Relevance
“…Between annealing protocols, the sample was heated well above T C , typically to 390 K at 1 K/min and subsequently cooled down 21 to reverse any previous diffusion and to ensure that the hydrogen is uniformly distributed as at this temperature the recombination speed is in the range of minutes. 17 We hereafter call this the recombined state. The sample was cooled down to the temperature of interest, T A , and kept at T A for a period of time lasting between several hours and 3 days.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Between annealing protocols, the sample was heated well above T C , typically to 390 K at 1 K/min and subsequently cooled down 21 to reverse any previous diffusion and to ensure that the hydrogen is uniformly distributed as at this temperature the recombination speed is in the range of minutes. 17 We hereafter call this the recombined state. The sample was cooled down to the temperature of interest, T A , and kept at T A for a period of time lasting between several hours and 3 days.…”
Section: Methodsmentioning
confidence: 99%
“…Details of the sample preparation are given elsewhere. 17 Magnetization measurements were performed using a commercial vibrating sample magnetometer (Quantum Design PPMS). Since the magnetic state of the sample strongly depends on its annealing history, the latter will be given in detail.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations