2016
DOI: 10.1515/msac-2016-0007
|View full text |Cite
|
Sign up to set email alerts
|

Reversed-Phase High-Performance Liquid Chromatography Analysis of β-Lactoglobulin and α-Lactalbumin in Different Types of Milk

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…The elution order shows BSA and α -La eluted before βlactglobulins. For β-Lg B were eluted before β-Lg A [10,13,37]. In chromatogram of Figure 1b can be observed a good separation of each studied proteins and the small peaks that are attributable to the other minor protein present in Milk Serum sample.…”
Section: Validation Of Hplc Methodmentioning
confidence: 86%
See 1 more Smart Citation
“…The elution order shows BSA and α -La eluted before βlactglobulins. For β-Lg B were eluted before β-Lg A [10,13,37]. In chromatogram of Figure 1b can be observed a good separation of each studied proteins and the small peaks that are attributable to the other minor protein present in Milk Serum sample.…”
Section: Validation Of Hplc Methodmentioning
confidence: 86%
“…Nowadays, a variety of methods have been developed to analyses whey proteins: reversedphase high performance liquid chromatography (RP-HPLC) [5,[8][9][10], ultra HPLC tandem mass spectrometry [9,[11][12][13][14][15], electrophoretic techniques [9,16,17], immunoaffinity chromatography( [18,19], Enzyme Linked Immunosorbent Assay (ELISA) [20] [21] and a novel visualized microarray method [22]. However, HPLC method allows rapid and automated analysis, characterized by good separations, high resolutions and accuracy and reproducible results, especially for simultaneous detection of multiple whey proteins.…”
Section: Introductionmentioning
confidence: 99%
“…The elution order ( Figure 1a ) shows that BSA and α-La protein were eluted before the β-lactoglobulins components (β-Lg A and B). Also, the β-Lg B protein was eluted before β-Lg A protein [ 11 , 14 , 35 ].…”
Section: Resultsmentioning
confidence: 99%
“…Recently, the researchers have developed a variety of methods to analyze whey proteins like as: reversed-phase high-performance liquid chromatography (RP-HPLC) [ 5 , 8 11 ], ultra-HPLC tandem mass spectrometry [ 10 , 12 16 ], electrophoretic techniques [ 10 , 17 , 18 ], immunoaffinity chromatography [ 19 , 20 ]. Enzyme-linked immunosorbent assay (ELISA) [ 21 , 22 ] and a novel visualized microarray method [ 23 ].…”
Section: Introductionmentioning
confidence: 99%
“…To date, many analytical methods have been developed to detect β-Lg. Traditional chromatography is commonly used for β-Lg monitoring, including high performance liquid chromatography (HPLC), 10 ultra-high performance liquid chromatography (UHPLC), 11 and liquid chromatography tandem mass spectrometry (LC-MS/MS). 12 In addition, some novel detection methods, such as enzyme-linked immunosorbent assay, 13 photoelectrochemical immunoassay, 14 lateral flow immunoassay, 15 real-time quantitative polymerase chain reaction, 16 transient isotachophoresis, 17 and molecular imprinting, 18 have also been used for the detection of β-Lg.…”
Section: Introductionmentioning
confidence: 99%