Retention of a telescopic overdenture on customized abutments after the simulation of 1 year in function

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…The results also showed that regardless of the material, both groups showed a significant decrease in retentive forces after simulation of 3 months of partial denture use. It has been suggested that any attachment system is subjected to functional loads resulting from the friction between the telescopic copings which lead to lowering the retentive force values [49].…”
Section: Discussionmentioning
confidence: 99%
“…The results also showed that regardless of the material, both groups showed a significant decrease in retentive forces after simulation of 3 months of partial denture use. It has been suggested that any attachment system is subjected to functional loads resulting from the friction between the telescopic copings which lead to lowering the retentive force values [49].…”
Section: Discussionmentioning
confidence: 99%
“…It is now evident in the literature that the levels of inflammation of the peri implant sulcus, also as a function of the different biological width and therefore of the different implant type, must be maintained and controlled, and to favor this it is necessary that the implant supported prosthesis guarantees excellent marginal closures, cleanable profiles, and does not favor the accumulation of plaque [52][53][54]. The shock absorbance as a feature of this implant material is extremely relevant, and allows for performing an implant rehabilitation, even complete, with interesting mechanical and biological characteristics: It is known that overload cannot directly cause peri-implantitis, but participates as a factor, together with the levels of inflammation that it maintains higher as a stimulus for bone resorption, in the development of implant pathology [20].…”
Section: Discussionmentioning
confidence: 99%
“…The chambers of the chewing simulator were lled with arti cial saliva prepared in the pharmaceutical industry lab, Faculty of Pharmacy, Ain-Shams University according to the formula adopted from Glandosane®; Fresenius Kabi Ltd, Germany [49,50]. Bi-axial cyclic loading of 240000 cycles at room temperature were applied to each model simulating one year of clinical service [49][50][51] (Fig. 12).…”
Section: Aging Proceduresmentioning
confidence: 99%
“…Based on the assumption that under regular conditions, a patient inserts and removes his denture with an average of four cycles/day (after every meal and before sleep time), A total of 1440 insertion/removal cycles were applied for each partial denture corresponding to one year of clinical service. [51][52][53] This was followed by mounting each model with the corresponding partial denture again in the universal testing machine to assess the induced strain at the abutments and the edentulous ridge.…”
Section: Aging Proceduresmentioning
confidence: 99%