1991
DOI: 10.1016/s0021-9614(05)80295-2
|View full text |Cite
|
Sign up to set email alerts
|

Results of (pressure, density, temperature) measurements on methane and on nitrogen in the temperature range from 273.15 K to 323.15 K at pressures up to 12 MPa using a new apparatus for accurate gas-density measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

5
43
0

Year Published

1996
1996
2010
2010

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 61 publications
(48 citation statements)
references
References 17 publications
5
43
0
Order By: Relevance
“…With the exception of the measuring runs of Friedman, (25) Canfield et al, (26) and Crain and Sonntag (28) nearly all data points confirm each other within the experimental uncertainty of this work. In particular, the (p, r, T ) values of Pieperbeck et al, (34) Guo et al, (31) and Duschek et al (7) are in excellent agreement with the new values, mostly to within =5·10 −5 ·r =. (The apparatus used by Pieperbecket al, (34) and Guo et al, (34) is also a ''Two-Sinker-Densimeter'' which was designed by our group (34) especially for density measurements in the gas region; this apparatus is at the laboratories of Ruhrgas AG in Dorsten, Germany.…”
Section: Discussionsupporting
confidence: 68%
See 4 more Smart Citations
“…With the exception of the measuring runs of Friedman, (25) Canfield et al, (26) and Crain and Sonntag (28) nearly all data points confirm each other within the experimental uncertainty of this work. In particular, the (p, r, T ) values of Pieperbeck et al, (34) Guo et al, (31) and Duschek et al (7) are in excellent agreement with the new values, mostly to within =5·10 −5 ·r =. (The apparatus used by Pieperbecket al, (34) and Guo et al, (34) is also a ''Two-Sinker-Densimeter'' which was designed by our group (34) especially for density measurements in the gas region; this apparatus is at the laboratories of Ruhrgas AG in Dorsten, Germany.…”
Section: Discussionsupporting
confidence: 68%
“…In particular, the (p, r, T ) values of Pieperbeck et al, (34) Guo et al, (31) and Duschek et al (7) are in excellent agreement with the new values, mostly to within =5·10 −5 ·r =. (The apparatus used by Pieperbecket al, (34) and Guo et al, (34) is also a ''Two-Sinker-Densimeter'' which was designed by our group (34) especially for density measurements in the gas region; this apparatus is at the laboratories of Ruhrgas AG in Dorsten, Germany. The measurements of Duschek et al (14) were carried out for special purposes 10 years ago.…”
Section: Discussionsupporting
confidence: 68%
See 3 more Smart Citations