2005
DOI: 10.1016/j.biortech.2004.09.026
|View full text |Cite
|
Sign up to set email alerts
|

Respirometric assays at fixed and process temperatures to monitor composting process

Abstract: A static respirometer was built to determine the Respirometric Index (RI) of composting samples at different temperatures. Composted materials were dewatered sludge (DS) and dewatered anaerobically digested sludge (ADS) obtained from a wastewater treatment plant. Respirometric indexes were obtained at a fixed value of 37 ºC (RI 37 ) and at the in situ temperature of the reactor at the moment of sampling (RI T ). Results indicated that both indexes correlated well with temperature evolution in the compost… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
56
0
1

Year Published

2006
2006
2020
2020

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 95 publications
(64 citation statements)
references
References 14 publications
3
56
0
1
Order By: Relevance
“…Static Respiration Index (SRI) was determined using a static respirometer based on the model previously described by Ianotti et al (1993) and according to the method described by Barrena et al (2005). Briefly, the drop of oxygen content in a flask containing a waste representative sample (250 g) was monitored with an oxygen meter (Lutron 5510, Lutron, Taiwan) connected to a personal computer (RS232 communication protocol) with in-house developed software to register oxygen values.…”
Section: Static Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Static Respiration Index (SRI) was determined using a static respirometer based on the model previously described by Ianotti et al (1993) and according to the method described by Barrena et al (2005). Briefly, the drop of oxygen content in a flask containing a waste representative sample (250 g) was monitored with an oxygen meter (Lutron 5510, Lutron, Taiwan) connected to a personal computer (RS232 communication protocol) with in-house developed software to register oxygen values.…”
Section: Static Methodsmentioning
confidence: 99%
“…However, in the solid waste treatment, there is no a consensus within the research community. At this moment, some assays have been developed, under aerobic (Scaglia et al, 2000;Adani et al, 2001;Adani et al, 2004a;Barrena et al, 2005) and anaerobic conditions (Ligthart and Nieman, 2002;Hansen et al, 2004). These assays are usually based on respirometric techniques (static and dynamic) and methanogenic activity assays.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A static respirometer was built according to an original model previously described (Ianotti et al, 1993) (Barrena et al, 2005).…”
Section: Respiration Testsmentioning
confidence: 99%
“…Results of the static respiration index (RI) are presented as an average of three replicates. A detailed description of the RI calculation can be found elsewhere (Barrena et al, 2005). Samples for respiration index were periodically obtained at day 0, 14, 28, 42 and 50.…”
Section: Respiration Testsmentioning
confidence: 99%