2021
DOI: 10.12659/msm.928804
|View full text |Cite
|
Sign up to set email alerts
|

Respiratory Variations in Peak Peripheral Artery Velocities and Waveforms for Rapid Assessment of Fluid Responsiveness in Traumatic Shock Patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

1
18
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(19 citation statements)
references
References 5 publications
1
18
0
Order By: Relevance
“…Two subgroups of the Roehrig et al 68 study could not be utilized for statistical analysis as the sensitivity and specificity values were not provided. Six different carotid parameters were identified, in descending frequency of use [number of subgroups in parentheses] these were as follows: corrected flow time (FTc) [9], 40,41,44 change in carotid Doppler peak velocity (∆CDPV) [9], 26,29,[41][42][43]47,[68][69][70] change in carotid artery velocity-time integral ∆CAVTI [4], 42,46 carotid Doppler peak velocity (CDPV) [2], 43,68 carotid Doppler flow (CDF) [1], 68 and change in corrected flow time ∆FTc [1]. 45 The method of obtaining carotid Doppler parameters is outlined well in existing literature.…”
Section: Study Selection and Study Characteristicsmentioning
confidence: 99%
See 4 more Smart Citations
“…Two subgroups of the Roehrig et al 68 study could not be utilized for statistical analysis as the sensitivity and specificity values were not provided. Six different carotid parameters were identified, in descending frequency of use [number of subgroups in parentheses] these were as follows: corrected flow time (FTc) [9], 40,41,44 change in carotid Doppler peak velocity (∆CDPV) [9], 26,29,[41][42][43]47,[68][69][70] change in carotid artery velocity-time integral ∆CAVTI [4], 42,46 carotid Doppler peak velocity (CDPV) [2], 43,68 carotid Doppler flow (CDF) [1], 68 and change in corrected flow time ∆FTc [1]. 45 The method of obtaining carotid Doppler parameters is outlined well in existing literature.…”
Section: Study Selection and Study Characteristicsmentioning
confidence: 99%
“…Five different CO measures were used to identify fluid responders. In descending frequency of use [number of subgroups in parentheses], these were as follows: transthoracic echocardiography (TTE) velocitytime integral (VTI) [8], 42,43,46,47 PiCCO (PULSION Medical Systems AG) [6], 40,69,70 pulmonary artery catheter (PAC) [5], 26,29,68 FloTrac (Edwards Lifesciences) [5], 44,45 and LiDCO (LiDCO Ltd) [2]. 41 Six studies (15 subgroups) were conducted on surgical patie nts, 26,40,41,44,45,68 whereas 7 studies (11 subgroups) were conducted on intensive care patients.…”
Section: Study Selection and Study Characteristicsmentioning
confidence: 99%
See 3 more Smart Citations