2004
DOI: 10.1002/bmc.398
|View full text |Cite
|
Sign up to set email alerts
|

Resolution of (±)‐ibuprofen using (−)‐brucine as a chiral selector by thin layer chromatography

Abstract: The enantiomeric resolution of (+/-)-ibuprofen into its enantiomers was achieved by TLC on silica gel plate using optically pure (-)-brucine as a chiral selector and acetonitrile-methanol (5:1, v/v) as the solvent system. Spots were located in an iodine chamber. The detection limit was 4.9 microg. The effect of concentration of the chiral selector, temperature and pH on resolution has been studied.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 16 publications
0
14
0
Order By: Relevance
“…For instance, enantioselectivity using brucine arises due to the formation of two diastereomers through simple ionic interactions between racemate and chiral selector, e.g. (+)-citalopram/brucine and (−)-citalopram/brucine 30. The enantiomeric resolution by HP-β-CD may involve the inclusion of drug within the CD cavity relative to the comparability of sizes, shapes and hydrophibicities.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…For instance, enantioselectivity using brucine arises due to the formation of two diastereomers through simple ionic interactions between racemate and chiral selector, e.g. (+)-citalopram/brucine and (−)-citalopram/brucine 30. The enantiomeric resolution by HP-β-CD may involve the inclusion of drug within the CD cavity relative to the comparability of sizes, shapes and hydrophibicities.…”
Section: Resultsmentioning
confidence: 99%
“…The method was validated according to ICH regulations by documenting its linearity, accuracy, precision, limit of detection and quantification, specificity and, robustness 30,33. The good linearity was obtained for seven concentrations in the range of 0.5– 40 μg/spot as shown in Figure 5.…”
Section: Resultsmentioning
confidence: 99%
“…In addition, resolution of (±)-ibuprofen using (-)-brucine (Bhushan and Gupta, 2004) and L-arginine (Bhushan and Parshad, 1996) impregnated TLC plates, (±)-verapamil using macrocyclic antibiotic as chiral selector in TLC (Bhushan and Gupta, 2005) and (±)-thioridazine using β-CD based CSP by HPLC (Bhushan and Gupta, 2006b) has also been reported.…”
Section: Introductionmentioning
confidence: 95%
“…Enantiomeric resolution of ibuprofen in pharmaceutical preparations has been reported (Bhushan and Gupta, 2004;Bhushan and Thiongo, 1999;Bhushan and Parshad, 1996).…”
Section: Introductionmentioning
confidence: 98%