2007
DOI: 10.1016/j.sna.2006.08.010
|View full text |Cite
|
Sign up to set email alerts
|

Residual magnetic field sensing for stress measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
87
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 164 publications
(104 citation statements)
references
References 9 publications
0
87
0
Order By: Relevance
“…(c) Localized stresses of order of 50 MPa in a demagnetized sample cannot produce measurable variation of the stray field. This fact was reported by [8], who gave an explanation derived from Jiles' theory. Our sensitivity analysis corroborates that statement.…”
Section: Discussion Of Resultsmentioning
confidence: 52%
See 2 more Smart Citations
“…(c) Localized stresses of order of 50 MPa in a demagnetized sample cannot produce measurable variation of the stray field. This fact was reported by [8], who gave an explanation derived from Jiles' theory. Our sensitivity analysis corroborates that statement.…”
Section: Discussion Of Resultsmentioning
confidence: 52%
“…In literature [8,25] it was shown, that the presence of magnetized clamps may produce an increase of stray field by an order of magnitude, and produce an uncontrollable remanent induction within the sample. (b) Unlike other authors [8,25], Roskosz and Bieniek extend their measurements over the notched portion of the sample, focusing on the peak found over the geometrical discontinuity. The potential geometrical effect is neglected in their interpretation.…”
Section: Reinterpreted Experiments 'E1' By Roskosz and Bieniekmentioning
confidence: 99%
See 1 more Smart Citation
“…This technique relies on the self magnetization of ferromagnetic structures by ambient magnetic fields such as the Earth's field (Wilson et al, 2007). It measures changes in the self magnetic leakage field of the ferromagnetic structures due to geometrical discontinuities and high density dislocations.…”
Section: Challenges and Future Applicationsmentioning
confidence: 99%
“…14 Moreover, it does not require special magnetization devices and the tested surface does not require a special treatment. Therefore, the MMM technology has been widely applied to inspect pressure vessels, 15 piping 16 and other equipment in service. The first pilot results of a fatigue-damage analysis obtained with the BNA and MMM methods have been already reported.…”
Section: Introductionmentioning
confidence: 99%