2014
DOI: 10.1016/j.ab.2014.05.004
|View full text |Cite
|
Sign up to set email alerts
|

Residual bovine serum albumin (BSA) quantitation in vaccines using automated Capillary Western technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
22
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 50 publications
(26 citation statements)
references
References 20 publications
3
22
0
Order By: Relevance
“…This further emphasises the value of using orthogonal techniques to quantify proteins across a wide dynamic range, or small proteins where options for Q-peptides are restricted. In our hands both quantitative platforms demonstrated an equivalently high level of precision using DOSCAT, which was within the range typically reported for SRM and QWB (using Simple Western technology) assays32728. Using ‘classic’ western blotting, it would be anticipated that reproducibility would be lower due to the greater number of manual handling steps.…”
Section: Resultssupporting
confidence: 80%
“…This further emphasises the value of using orthogonal techniques to quantify proteins across a wide dynamic range, or small proteins where options for Q-peptides are restricted. In our hands both quantitative platforms demonstrated an equivalently high level of precision using DOSCAT, which was within the range typically reported for SRM and QWB (using Simple Western technology) assays32728. Using ‘classic’ western blotting, it would be anticipated that reproducibility would be lower due to the greater number of manual handling steps.…”
Section: Resultssupporting
confidence: 80%
“…They reported that the technology increased the efficiency of analytical testing and could more effectively guide process development [63]. The group also developed a new improved method for detection of residual BSA to meet quality control requirements in vaccine production [64]. …”
Section: Applicationsmentioning
confidence: 99%
“…BSA has the same composition as HSA [6,7]. So far, a lot of methods have been established for the detection and determination of BSA such as light scattering technique [10], near-infrared diffusion reflectance spectroscopy [11], capillary electrophoresis [12], molecular imprinted polymer (MIP) based electrochemistry [13] and flow injection chemiluminescence [14]. Although some of these methods display high selectivity and good sensitivity, they suffer from complicated sensor pretreatments and instrumentations, high costs and skilled operators requirements.…”
Section: Introductionmentioning