2021
DOI: 10.1016/j.yofte.2020.102408
|View full text |Cite
|
Sign up to set email alerts
|

Research on simultaneous temperature and relative humidity measurement based on tapered PCF Mach-Zehnder interferometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 27 publications
0
2
0
Order By: Relevance
“…In 2020, Chunmei et al proposed a sensing structure based on a Fabry-Perot cavity (FPC) and Sagnac loops for measurement of temperature and strain, the FPC consists of a micropiece of chemical etched multimode fiber end face, welded with another single mode fiber [10]. In 2021, Jietong et al fabricated the MZI based on tapered PCF which was sandwiched between two SMFS for simultaneous temperature and relative humidity (RH) [11]. In 2021, Xun et al presented a hybrid sapphire dual-Fabry-Perot cavities sensor using a double-sided polished sapphire solid wafer in series with a double-sided parallel sapphire C-ring and a single-sided polished sapphire mirror to form the hybrid Fabry-Perot interferometer for high temperature and RI measurement [12].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In 2020, Chunmei et al proposed a sensing structure based on a Fabry-Perot cavity (FPC) and Sagnac loops for measurement of temperature and strain, the FPC consists of a micropiece of chemical etched multimode fiber end face, welded with another single mode fiber [10]. In 2021, Jietong et al fabricated the MZI based on tapered PCF which was sandwiched between two SMFS for simultaneous temperature and relative humidity (RH) [11]. In 2021, Xun et al presented a hybrid sapphire dual-Fabry-Perot cavities sensor using a double-sided polished sapphire solid wafer in series with a double-sided parallel sapphire C-ring and a single-sided polished sapphire mirror to form the hybrid Fabry-Perot interferometer for high temperature and RI measurement [12].…”
Section: Introductionmentioning
confidence: 99%
“…, respectively. According to equation(10), wavelength drift can be expressed in matrix form as:In equation(11), the first item on the right side of the equation is called the sensitivity matrix K and simplified to obtain the change value of temperature and strain as follows: is the characteristic equation of the sensor, where K −1 is the inverse matrix of the sensitivity matrix K, as shown in equation(13).…”
mentioning
confidence: 99%