2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia) 2016
DOI: 10.1109/ipemc.2016.7512510
|View full text |Cite
|
Sign up to set email alerts
|

Research on power coordinated control strategy of wind turbine-based DC microgrid under various modes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…12a. When the load current is increased to mi op−m , each current of the m converters will be i op−m , then according to (26) and (27), the following can be obtained: Thus, from (27), it can be found that the m converters' compensate value for voltage reference is changed to the initial compensate value of priority (m + 1) converter According to (26), the current will be shared by the (m + 1) converters as shown in Fig. 12a, and…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…12a. When the load current is increased to mi op−m , each current of the m converters will be i op−m , then according to (26) and (27), the following can be obtained: Thus, from (27), it can be found that the m converters' compensate value for voltage reference is changed to the initial compensate value of priority (m + 1) converter According to (26), the current will be shared by the (m + 1) converters as shown in Fig. 12a, and…”
Section: Resultsmentioning
confidence: 99%
“…12b. When the load current is decreased to (m − 1)i op−(m−1) , each current of the m converters will be (m − 1)i op−(m−1)/m , then according to (26) and (27), the following can be obtained:…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…As the absolute error is less than e 1k , Δk pk returns to zero to eliminate the error rapidly and guarantee good stead-state performance. According to (3), the relationship between the n converters' threshold values can be obtained as 11…”
Section: Small Proportional Termmentioning
confidence: 99%
“…In the aforementioned applications, the droop control is often used by imposing virtual resistance in order to achieve autonomous (communication-less) current sharing among paralleled converters [9]- [11]. When using droop control methods, also named primary control, the major concern of previous works are focused on the secondary and tertiary control levels inside the hierarchical control structure according to voltage deviations caused by line impedance [12]- [16], state of charge (SoC) for battery management systems [17]- [19], power losses [19]- [22], and communication algorithms [16], [22]- [23].…”
Section: Introductionmentioning
confidence: 99%