Research on Inverter Integrated Reactive Power Control Strategy in the Grid-Connected PV Systems

Abstract: In order to solve the problems caused by the susceptibility to changing weather conditions and the complex load conditions of photovoltaic (PV) systems, and the fact a single target inverter control strategy cannot effectively mitigate large voltage fluctuations at point of common coupling (PCC), an integrated reactive power control strategy for PV inverters is proposed. According to the weather and load conditions, this strategy is divided into four control modes: normal operation control mode, reverse power … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(17 citation statements)
references
References 26 publications
0
16
0
1
Order By: Relevance
“…Possibly, reactive power supply even in periods of low or no irradiance, i.e., no active power generation (nighttime mode or var at night mode) could be of benefit to the distribution power system. Several examples of such inverter topologies and control schemes can be found (e.g., [16][17][18][19][20][21][22]). To cover power losses during reactive power supply, the inverter has to absorb active power from the grid or from an internal energy storage.…”
Section: Analysis Of Reactive Power Compensation By Pv Invertersmentioning
confidence: 99%
See 1 more Smart Citation
“…Possibly, reactive power supply even in periods of low or no irradiance, i.e., no active power generation (nighttime mode or var at night mode) could be of benefit to the distribution power system. Several examples of such inverter topologies and control schemes can be found (e.g., [16][17][18][19][20][21][22]). To cover power losses during reactive power supply, the inverter has to absorb active power from the grid or from an internal energy storage.…”
Section: Analysis Of Reactive Power Compensation By Pv Invertersmentioning
confidence: 99%
“…One PV source per each feeder is considered to be the case of medium PV dispersion rate (8.5 MVA total peak power). Although different control schemes are proposed for finding the optimum level of reactive power generation (e.g., [2,11,22,[26][27][28]), in this research, uniform reactive power generation of individual PV sources is assumed. In fact, the focus of the research was to investigate reactive power generation influence on the overall system behavior.…”
Section: One Pv Source Per Each Feedermentioning
confidence: 99%
“…If the compensator voltage magnitude is smaller than the voltage at the connection point, reactive power will be consumed by the STATCOM. On the other hand, if the situation is opposite, reactive power will be delivered to the grid . This principle is presented in the Figure .…”
Section: Reactive Power Compensationmentioning
confidence: 99%
“…They need to connect to the grid to function, and they can send excess power generated back to the grid when the energy consumption of the building or facility is low. Moreover, these systems are characterized by low costs, high efficiency, strong scalability and high reliability [52][53][54][55][56][57].…”
Section: Popular Pv Inverter Technologies and Systems In Hungarymentioning
confidence: 99%