2019
DOI: 10.1049/joe.2018.8392
|View full text |Cite
|
Sign up to set email alerts
|

Research on antenna for detecting the corona discharge of transmission line

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 17 publications
(14 reference statements)
0
3
0
Order By: Relevance
“…However, monitoring and localization accuracy tend to be adversely affected because of noises and interferences superimposed with the RF signals, so there is a need to apply denoising algorithms [33]. RF antennas have been used to detect electromagnetic waves generated by corona and PD from transmission lines [34], switchgear [35], cables or transformers [36], among others. By using specific antenna array configurations can also locate the discharge points [18] by measuring the attenuation of the radio frequency signals [35].…”
Section: Pressure Effect On Electrical Breakdown Partial Discharges and Coronamentioning
confidence: 99%
“…However, monitoring and localization accuracy tend to be adversely affected because of noises and interferences superimposed with the RF signals, so there is a need to apply denoising algorithms [33]. RF antennas have been used to detect electromagnetic waves generated by corona and PD from transmission lines [34], switchgear [35], cables or transformers [36], among others. By using specific antenna array configurations can also locate the discharge points [18] by measuring the attenuation of the radio frequency signals [35].…”
Section: Pressure Effect On Electrical Breakdown Partial Discharges and Coronamentioning
confidence: 99%
“…In the study of abnormal discharge in transmission equipment, based on the generation of radio frequency electromagnetic waves during discharge, the frequency range of electromagnetic waves is mainly concentrated between 200 MHz and 300 MHz. Therefore, discharge detection can be achieved through radio frequency antennas [3]. The Hilbert fractal antenna is a microstrip antenna based on the shape of Hilbert fractal geometry, which is a research hotspot [4][5].…”
Section: Introductionmentioning
confidence: 99%
“…In addition, the sensitivity of conventional electromagnetic methods may be insufficient to detect PD activity at low pressures, as the amplitude of PD pulses typically decreases with pressure [ 35 ]. PD activity is typically detected using radio interference voltage (RIV) detectors, electromagnetic PD detectors, sound level meters [ 38 ] or radio frequency [ 39 ], and ultrahigh frequency antennas [ 40 , 41 ]. Surface PD activity can also be detected using optical methods [ 37 , 42 , 43 , 44 ], such as optical spectrophotometers [ 45 ], due to the ultraviolet (UV) and visible light emissions.…”
Section: Introductionmentioning
confidence: 99%