2012
DOI: 10.1093/jicru/ndt006
|View full text |Cite
|
Sign up to set email alerts
|

Report 87

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(16 citation statements)
references
References 0 publications
0
14
0
Order By: Relevance
“…One of the often mentioned constraints is that these measurements are complex and time consuming. 41,42 This constraint has been lifted by our Compton spectrometer design for use at CT scanners as for the positioning of the spectrometer, the alignment lasers of the scanner can be used, leading to setting-up times of typically 10-15 min. Combined with spectrum acquisition times of about 5 min per spectrum, a protocol for measuring spectra at two or three energies will not last more than 30-45 min.…”
Section: B Clinical Ct Scannersmentioning
confidence: 99%
“…One of the often mentioned constraints is that these measurements are complex and time consuming. 41,42 This constraint has been lifted by our Compton spectrometer design for use at CT scanners as for the positioning of the spectrometer, the alignment lasers of the scanner can be used, leading to setting-up times of typically 10-15 min. Combined with spectrum acquisition times of about 5 min per spectrum, a protocol for measuring spectra at two or three energies will not last more than 30-45 min.…”
Section: B Clinical Ct Scannersmentioning
confidence: 99%
“…The MTF was calculated using a 50 µm tungsten wire source. This wire source is used to calculate a point spread function (PSF), from which the MTF was computed using a Fourier transform, and normalized to the average intensity of the PSF [55]: containing 5 modules (The Phantom Laboratory, Salem, NY, USA). The phantom was positioned in the isocenter o the scanner as suggested by the user manual [54].…”
Section: Image Quality Of a Dual-layer Ct | Chaptermentioning
confidence: 99%
“…The module was used to measure the accuracy of the system by calculating a mean CT number, and to characterize noise by calculating the standard deviation (SD) of the mean CT number and by measuring the noise power spectrum (NPS). Nine ROIs of 64×64 voxels were selected in the uniform material, o which the SD was calculated and the 2D NPS was computed using the discrete Fourier transform [55]:…”
Section: Image Quality Of a Dual-layer Ct | Chaptermentioning
confidence: 99%
See 2 more Smart Citations