Repeatability of Oculus Pentacam Metrics Derived From Corneal Topography

Abstract: The Oculus Pentacam provides repeatable measures of the metrics derived from corneal topography over the tested time scales. In subjects aged from 19 to 40 years, topography measurements and their respective variability did not seem to change significantly with age.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
18
0
1

Year Published

2012
2012
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(20 citation statements)
references
References 49 publications
1
18
0
1
Order By: Relevance
“…4,23,24 For manual keratometry, the reported s w ranges from 0.08 D (3 repeated measurements) to 0.10 D (10 repeated measurements). 23,33 The s w of the Pentacam device in measuring the anterior corneal radius is reported to be 0.02 mm (3 repeated measurements), which corresponds to an s w of 0.80 D. 34 To our knowledge, no previous studies have examined the s w of repeated measurements obtained with the SMI Reference Unit or KR-1W corneal topographer. Ideally, before calculating the toric IOL cylinder power in each patient, a series of repeated measurements should be obtained to ensure that the repeatability of the magnitude and the meridian of astigmatism is acceptable.…”
Section: Discussionmentioning
confidence: 99%
“…4,23,24 For manual keratometry, the reported s w ranges from 0.08 D (3 repeated measurements) to 0.10 D (10 repeated measurements). 23,33 The s w of the Pentacam device in measuring the anterior corneal radius is reported to be 0.02 mm (3 repeated measurements), which corresponds to an s w of 0.80 D. 34 To our knowledge, no previous studies have examined the s w of repeated measurements obtained with the SMI Reference Unit or KR-1W corneal topographer. Ideally, before calculating the toric IOL cylinder power in each patient, a series of repeated measurements should be obtained to ensure that the repeatability of the magnitude and the meridian of astigmatism is acceptable.…”
Section: Discussionmentioning
confidence: 99%
“…It has been described before that the Pentacam is a reliable tool for anterior segment examination with high repeatability and good intra-observer reliability [17][18][19][20]. It was the main aim of the undertaken investigation to analyze the changes in anterior chamber architecture induced by LPI in patients with one-sided angle closure crisis in the eye suffering from acute crisis and in the fellow eye.…”
Section: Introductionmentioning
confidence: 99%
“…As we moved peripherally, the correlation remained high, albeit not as strong as that in the central area. Similarly, other authors have reported an increase in variability in corneal pachymetry measurements from the center to the periphery, particularly in the superior cornea (4,(14)(15)(16)(17) . They attributed this variability to the effects of the superior eyelid (4) .…”
Section: Discussionmentioning
confidence: 99%
“…Similarly, other authors have reported an increase in variability in corneal pachymetry measurements from the center to the periphery, particularly in the superior cornea (4,(14)(15)(16)(17) . They attributed this variability to the effects of the superior eyelid (4) . We believe that the differences observed in paracentral (peripheral) values were very pre dictable because small decentration in the BFS would lead to a false high value, considering that the peripheral cornea is farther away from the BFS because of its prolate shape.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation