2019
DOI: 10.1016/j.seppur.2019.115703
|View full text |Cite
|
Sign up to set email alerts
|

Removing phenolic pollutants using Deep Eutectic Solvents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
41
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 78 publications
(48 citation statements)
references
References 28 publications
2
41
0
Order By: Relevance
“…In order to develop the GC and AC models, the most up-to-date databanks of various types of DESs were collected from the literature. The databanks involved 1239 data points from 149 DESs for density 35 66 , 1117 data points from 142 DESs for refractive index 11 , 39 , 41 43 , 47 , 50 , 54 , 57 , 59 , 63 , 64 , 67 87 , 461 data points from 24 DESs for heat capacity 59 , 70 , 88 93 , 398 data points from 37 DESs for speed of sound 42 , 43 , 67 , 72 , 75 , 77 , 82 , 94 100 and 538 data points from 98 DESs for surface tension 47 , 63 , 71 , 80 , 86 , 87 , 101 – 116 . All of the data were at atmospheric pressure.…”
Section: Methodsmentioning
confidence: 99%
“…In order to develop the GC and AC models, the most up-to-date databanks of various types of DESs were collected from the literature. The databanks involved 1239 data points from 149 DESs for density 35 66 , 1117 data points from 142 DESs for refractive index 11 , 39 , 41 43 , 47 , 50 , 54 , 57 , 59 , 63 , 64 , 67 87 , 461 data points from 24 DESs for heat capacity 59 , 70 , 88 93 , 398 data points from 37 DESs for speed of sound 42 , 43 , 67 , 72 , 75 , 77 , 82 , 94 100 and 538 data points from 98 DESs for surface tension 47 , 63 , 71 , 80 , 86 , 87 , 101 – 116 . All of the data were at atmospheric pressure.…”
Section: Methodsmentioning
confidence: 99%
“…DES were prepared using the approach described by Hadj‐Kali et al 27 The hydrogen bond acceptor and hydrogen bond donor were mixed in HBA:HBD molar ratio at room temperature and pressure until a homogenous liquid was formed 28 . Prior to their use, the solution was kept for 4 h to attain equilibrium.…”
Section: Methodsmentioning
confidence: 99%
“…Sas et al focused on the elimination of phenolic pollutants from water reservoirs using organic acids and DESs based on menthol. The findings obtained from similar RTILs were compared with the experimental data and was shown to be more advanced [73]. Silva et al employed magnetic ionic liquids to identify organic pollutants in river water samples [74].…”
Section: Environmental Applicationsmentioning
confidence: 99%