2021
DOI: 10.1016/j.electacta.2021.139254
|View full text |Cite
|
Sign up to set email alerts
|

Removal of antibiotic rifampicin from aqueous media by advanced electrochemical oxidation: Role of electrode materials, electrolytes and real water matrices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 50 publications
(11 citation statements)
references
References 67 publications
0
9
0
Order By: Relevance
“…From the results obtained in our previous work, the composite sensor exhibited an excellent response for detecting HCQ in H 2 SO 4 /ultrapure water solution. However, the use of ultrapure water with a single target pollutant could mask the applicability of the experimental data to actual uses [20] with real water matrices (which are composed by several inorganic and organic compounds that can affect the electrochemical sensor response to quantify HCQ). Then, this composite sensor was used to construct an analytical curve with a non-polluted river water matrix (see Table 1).…”
Section: Dpv Analytical Curve and Standard Additions Methods In River Water Samplementioning
confidence: 99%
See 1 more Smart Citation
“…From the results obtained in our previous work, the composite sensor exhibited an excellent response for detecting HCQ in H 2 SO 4 /ultrapure water solution. However, the use of ultrapure water with a single target pollutant could mask the applicability of the experimental data to actual uses [20] with real water matrices (which are composed by several inorganic and organic compounds that can affect the electrochemical sensor response to quantify HCQ). Then, this composite sensor was used to construct an analytical curve with a non-polluted river water matrix (see Table 1).…”
Section: Dpv Analytical Curve and Standard Additions Methods In River Water Samplementioning
confidence: 99%
“…Considering that several research groups are evaluating the treatment effectiveness of certain technologies by polluting in laboratory different water matrices (e.g., river, sea, groundwater, tap water, drinking water and so on) with a well-known amount of a single target pollutant for understanding the experimental data in order to translate to real applications [20]. Then, this work aims to electrochemically treat a real water matrix polluted with HCQ.…”
Section: Introductionmentioning
confidence: 99%
“…Another effective parameter on the electrochemical oxidation process of DCF is supported electrolyte so in the present study three doses of NaCl (0.1, 0.3 and 0.5 g NaCl) have been evaluated. Sodium chloride has good ionic strength and it exhibited very useful role in electrochemical degradation process of organic compounds compared to other electrolytes such as NaNO 3 , Na 2 SO 4 and Na 2 CO 3 (Brito et al 2021). Two different behaviors were observed for DCF elimination e ciency during the electrolysis process as depicted in Fig.…”
Section: Effect Of Supporting Electrolytes On Elimination Of Dcfmentioning
confidence: 99%
“…Cl 2 + H 2 O → HOCl + H + + Cl − (10) HOCl → H + + OCl − (11) It is well known that increasing applied voltage resulted in creasing in consumption energy, so the pro le of this relation has been presented in Fig. 5c.…”
Section: Effect Of Initial Concentration On Elimination Of Dcfmentioning
confidence: 99%
“…Considering the hazard posed by the persistent drugs in the environment, today there is an increasing trend in the development of various materials (green synthesized magnetic Fe 3 O 4 nanoparticles [ 98 ], water/dimethylsulfoxide-transcutol/isopropyl alcohol/capmul MCM C8 nanoemulsion [ 99 ], graphene hydrogel/M (M:Cu, Co, Ni nanocomposite) as cathode [ 100 ], Co 3 O 4 NPs supported on olive stone biochar [ 101 ], etc.) and processes (e.g., Fenton reaction, electrochemical process and their combination [ 102 ], electrochemical [ 103 ], etc.) for RIF removal from various water samples.…”
Section: Rifamycins Detection and Monitoringmentioning
confidence: 99%