2009
DOI: 10.1016/j.jhazmat.2009.01.043
|View full text |Cite
|
Sign up to set email alerts
|

Removal and recovery of Hg(II) from aqueous solution using chitosan-coated cotton fibers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
22
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 84 publications
(25 citation statements)
references
References 31 publications
3
22
0
Order By: Relevance
“…Similar phenomena were found in the adsorption of Hg(II) on chitosan-coated cotton fibers [26], and Ag(I) on amidoximated porous acrylonitrile/methyl acrylate copolymer beads [27], which was attributed to the presence of an energy barrier in the adsorption process and to the activated complex in the transition state in an excited form.…”
Section: Nsir Of a Contact Time Of 24 H And A Liquid/solid Ratio Of 1supporting
confidence: 69%
See 2 more Smart Citations
“…Similar phenomena were found in the adsorption of Hg(II) on chitosan-coated cotton fibers [26], and Ag(I) on amidoximated porous acrylonitrile/methyl acrylate copolymer beads [27], which was attributed to the presence of an energy barrier in the adsorption process and to the activated complex in the transition state in an excited form.…”
Section: Nsir Of a Contact Time Of 24 H And A Liquid/solid Ratio Of 1supporting
confidence: 69%
“…The Lagergren first order kinetics model and a pseudo second order model were used to investigate the dominant mechanism of the adsorption process. The Lagergren first order model is represented by the equation: [26] …”
Section: Adsorption Kineticsmentioning
confidence: 99%
See 1 more Smart Citation
“…Chen [39] and Hg 2+ on the chitosan-coated cotton fibers by Qu et al [40], which was attributed by these authors to the presence of an energy barrier in the adsorption process and to the activated complex in the transition state in an excited form.…”
Section: Adsorption Thermodynamicsmentioning
confidence: 93%
“…Moreover, the preconcentration step also separates the analyte from most of the matrix materials, and thus eliminates possible interferences, and lower detection limits are achieved. 16 Several techniques have been used for the preconcentration of mercury, such as solvent extraction 17 and solid-phase extraction by polymeric sorbents, 18,19 wool, 20 activated carbon, 21 chitosan, 22 chelating resins, 23 clay, 24 and other materials. 25,26 Particularly, polymeric sorbents have recently attracted more attention because of their larger sorption capacities, higher efficiencies and ease of preparation.…”
Section: Introductionmentioning
confidence: 99%