2011
DOI: 10.2116/analsci.27.833
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Mercury(II) in the Presence of Methylmercury after Preconcentration Using Poly(acrylamide) Grafted onto Cross-linked Poly(4-vinyl pyridine): Application to Mercury Speciation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 18 publications
(15 citation statements)
references
References 33 publications
0
14
0
Order By: Relevance
“…Yayayürük et al [33] have used the same adsorbent, for the first time, for the selective preconcentration of Hg(II) prior to cold-vapour atomic-fluorescence measurements, and separate determinations of Hg(II) and MeHg(I) at the trace level were performed at a ng L −1 level. In addition, adsorption isotherms were studied, and the affinity of the adsorbent to several metal ions, such as Pb(II), Zn(II), Cu(II), Cd(II) and Fe(III), was investigated.…”
Section: Polyacrylamide (Pam)mentioning
confidence: 99%
“…Yayayürük et al [33] have used the same adsorbent, for the first time, for the selective preconcentration of Hg(II) prior to cold-vapour atomic-fluorescence measurements, and separate determinations of Hg(II) and MeHg(I) at the trace level were performed at a ng L −1 level. In addition, adsorption isotherms were studied, and the affinity of the adsorbent to several metal ions, such as Pb(II), Zn(II), Cu(II), Cd(II) and Fe(III), was investigated.…”
Section: Polyacrylamide (Pam)mentioning
confidence: 99%
“…Moreover, in order to identify the selectivity of Cu(II) with respect to competitor ions (Al, Ba, Co, Mn, Mg, and Ni), the distribution and the selectivity coefficients of Cu(II) were obtained from equilibrium binding data using the equations given in a previous study (Yayayürük et al 2011). …”
Section: Sorption/desorption Studiesmentioning
confidence: 99%
“…Several analytical techniques have been used for mercury determination including, cold vapor atomic absorption spectrometry (CV-AAS) [11], cold vapor atomic fluorescence spectrometry (CV-AFS) [12,13], inductively coupled plasma atomic emission spectrometry (ICP-OES) [14] and inductively coupled plasma mass spectrometry (ICP-MS) [15], anodic or cathodic stripping voltammetry [16], neutron activation analysis chromatography [17], spectrofluorimetry [18], X-ray fluorescence spectrometry [19], ion selective electrodes [20], and gas chromatography [21].…”
Section: Introductionmentioning
confidence: 99%