2018
DOI: 10.1002/rcm.8045
|View full text |Cite
|
Sign up to set email alerts
|

Remote sampling mass spectrometry for dry samples: Sheath‐flow probe electrospray ionization (PESI) using a gel‐loading tip inserted with an acupuncture needle

Abstract: Because of its simplicity and versatility, sheath-flow PESI is a promising technique for on-site and nondestructive profile analysis of dry samples with bulky and complicated shapes, with a spatial resolution of ~0.3 mm.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
37
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(38 citation statements)
references
References 34 publications
(39 reference statements)
1
37
0
Order By: Relevance
“…The amount of sample required in sfPESI has been estimated to be in the order of picograms, thus the technique can be used with minute sample amounts. 28 Most importantly, the sequential ionisation observed with sfPESI enables the temporal separation of ions, offering the possibility of limiting ion suppression and visualising more analytes in such a way that has not been observed in other electrospray techniques such as LESA. The principles of this sequential ionisation have been described in greater detail in a recent paper by Usmanov et al 28…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The amount of sample required in sfPESI has been estimated to be in the order of picograms, thus the technique can be used with minute sample amounts. 28 Most importantly, the sequential ionisation observed with sfPESI enables the temporal separation of ions, offering the possibility of limiting ion suppression and visualising more analytes in such a way that has not been observed in other electrospray techniques such as LESA. The principles of this sequential ionisation have been described in greater detail in a recent paper by Usmanov et al 28…”
Section: Resultsmentioning
confidence: 99%
“…27 However as PESI is only applicable to liquid samples, sheath-ow PESI (sfPESI) was later developed to enable the analysis of non-liquid samples. 28,29 Sheath-ow PESI is a modication of the PESI technique in which the needle is contained within a solvent-lled gel-loading tip with a slight protrusion (0.1 mm) of the needle from the base. When the probe touches the sample surface, the convex liquid at the base of the probe wets the sample and enables analyte extraction from the surface.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…of PESI 136) . A metal needle is inserted into a gel loading tip containing solvent so that the needle tip protrudes slightly.…”
Section: Sheath Flow Pesi (Sf-pesi) Is a Derivative Technologymentioning
confidence: 99%
“…Sheath flow PESI (SF-PESI) is a derivative technology of PESI. 136 ) A metal needle is inserted into a gel loading tip containing solvent so that the needle tip protrudes slightly. Sample extraction is performed by touching the needle to the sample, and ESI is performed by applying a high voltage to the needle.…”
Section: Development and Application Of Direct Liquid Extraction And Ionizationmentioning
confidence: 99%