2019
DOI: 10.1049/joe.2018.8909
|View full text |Cite
|
Sign up to set email alerts
|

Reliability modelling and analysis on MMC for VSC‐HVDC by considering the press‐pack IGBT and capacitors failure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
3
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 4 publications
0
3
0
1
Order By: Relevance
“…O conversor CHBé composto de vários componentes que podem falhar por diferentes razões, como falhas em circuito aberto ou em curto-circuito nos IGBTs, falhas no capacitor da célula, falhas na fonte de alimentação ou falhas no gate driver [8], [9]. Para manter a operação do conversor após uma ou mais falhas, células adicionais (chamadas células redundantes) são integradasà estrutura do conversor [10].…”
Section: Resumo -unclassified
“…O conversor CHBé composto de vários componentes que podem falhar por diferentes razões, como falhas em circuito aberto ou em curto-circuito nos IGBTs, falhas no capacitor da célula, falhas na fonte de alimentação ou falhas no gate driver [8], [9]. Para manter a operação do conversor após uma ou mais falhas, células adicionais (chamadas células redundantes) são integradasà estrutura do conversor [10].…”
Section: Resumo -unclassified
“…Jing et al considered the correlation of sub-modules, analyzed the influence of different sub-module redundancy configuration schemes on the reliability of MMC, and finally obtained the joint probability distribution function of the converter arms [6]. Li et al considered the operating conditions of the converter valve, established a reliability model of the MMC valve based on the fault tree analysis method, and identified the weak links of the MMC valve [7]. Rong et al deduced the analytical expressions of the loss rate, power supply reliability, and redundancy of the full-bridge MMC converter valve.…”
Section: Introductionmentioning
confidence: 99%
“…The aforementioned study did not consider bypass switch refusal closing as a critical factor [4][5][6][7][8][9][10]. The VSC valve sub-module only needs to close the bypass switch when there is a fault, but if the bypass switch cannot be closed for some reason, the converter valve needs to be blocked to avoid expanding the fault range.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, they play an essential role in the operation of the MMCs and have to be extremely reliable. In all types of capacitors, due to features like self-healing, excellent ripple current performance, and low equivalent series resistance [2]- [4], metalized polypropylene film (MPPF) capacitors are typically used in MMC applications. Although MPPF capacitors can provide better reliability performance, they are not failure-free.…”
Section: Introductionmentioning
confidence: 99%