2013 Proceedings Annual Reliability and Maintainability Symposium (RAMS) 2013
DOI: 10.1109/rams.2013.6517682
|View full text |Cite
|
Sign up to set email alerts
|

Reliability analysis of a direct-liquid cooling system of direct drive permanent magnet synchronous generator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 7 publications
0
7
0
Order By: Relevance
“…In light of this some novel cooling methods targeting directly the heat directly inside the slot have been proposed. As described in [12][13][14][15][16][17], slot water jacket cooling provides an efficient way to reduce the winding hot spot temperature, albeit the copper losses are increased due to the space occupied by the slot jacket. Moreover due to electrical conductivity of water, it is imperative that sealing is ensured within such a configuration.…”
mentioning
confidence: 99%
“…In light of this some novel cooling methods targeting directly the heat directly inside the slot have been proposed. As described in [12][13][14][15][16][17], slot water jacket cooling provides an efficient way to reduce the winding hot spot temperature, albeit the copper losses are increased due to the space occupied by the slot jacket. Moreover due to electrical conductivity of water, it is imperative that sealing is ensured within such a configuration.…”
mentioning
confidence: 99%
“…This method consists of the hollow stator bars, phase connection rings, main leads, bushings, and neutral bus, that deionized water or oil past the hollow passages to remove the high temperature directly from the stator windings [63] and [64]. These types of cooling are mostly implemented on large synchronous machines [65], [66], and [67]. However, developing the AM method allows the designer to implement this thermal management system for small machines [68].…”
Section: ) Additive Manufacture Direct Liquid Cooling Windingmentioning
confidence: 99%
“…Performance comparisons of the PMs under different temperatures have been carried out in [6]. Different cooling strategies have been proposed for various designs of these machines involving liquid and forced-air cooling [7][8][9]. Reliability and the application of the cooling systems has been studied in [10,11].…”
Section: Introductionmentioning
confidence: 99%