2015
DOI: 10.1155/2015/189294
|View full text |Cite
|
Sign up to set email alerts
|

Relationship between Tibial Baseplate Design and Rotational Alignment Landmarks in Primary Total Knee Arthroplasty

Abstract: This study evaluated the influence of modern tibial baseplate designs when using the anterior tibial cortex as a primary rotational landmark for the tibial baseplate in TKA. Eighty patients undergoing TKA were randomized in two groups. Group 1 included 25 females and 15 males receiving a posterior-stabilized (PS) symmetric tibial baseplate while Group 2 included 24 females and 16 males receiving a PS anatomical tibial component. Identical surgical technique, including the use of the surgical transepicondylar f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
20
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 21 publications
(24 citation statements)
references
References 44 publications
(55 reference statements)
1
20
0
Order By: Relevance
“…Our results are amongst the best, with similar inter- and intra-observer reliability compared to other authors; for this, we have the following explanations: the reference points were specified in a precise manner and all three of the examiners followed the same protocol [ 6 , 8 , 22 , 23 , 26 , 27 , 29 31 , 34 , 35 , 39 , 42 , 44 , 48 ].…”
Section: Discussionsupporting
confidence: 78%
See 1 more Smart Citation
“…Our results are amongst the best, with similar inter- and intra-observer reliability compared to other authors; for this, we have the following explanations: the reference points were specified in a precise manner and all three of the examiners followed the same protocol [ 6 , 8 , 22 , 23 , 26 , 27 , 29 31 , 34 , 35 , 39 , 42 , 44 , 48 ].…”
Section: Discussionsupporting
confidence: 78%
“…The repeatability and reliability of the classic Berger method and its modifications were examined by several authors. Most of them mention good and excellent intra- and inter-observer intra-class correlation coefficients (ICC) [ 8 , 23 , 26 , 27 , 29 31 , 35 , 42 , 44 , 48 ].…”
Section: Discussionmentioning
confidence: 99%
“…At this point, the femoral component is fitted according to the femoral cuts, the anatomical tibial plateau is oriented following the medial third of the tibial tubercle, 16 and the MC insert trial is used evaluating the stability of the knee during the all range of motion (ROM) with the patella relocating on the femoral groove. When a wide ROM with a stable knee is restored, the final tibial insert is introduced.…”
Section: Methodsmentioning
confidence: 99%
“…The rotational alignment of the Persona anatomical tibial component is set according to the medial third of the tibial tubercle. 26 When it is felt that both gaps are balanced using standard instrumentation and with the trial components in place, the CR VERASENSE tibial sensor is inserted (Fig. 2).…”
Section: Surgical Technique For Primary Tka Using Load Sensorsmentioning