In 2012 we reviewed a consecutive series of 92 uncemented THRs performed between 1986 and 1991 at our institution using the CLS Spotorno stem, in order to assess clinical outcome and radiographic data at a minimum of 21 years. The series comprised 92 patients with a mean age at surgery of 59.6 years (39 to 77) (M:F 43;49). At the time of this review, seven (7.6%) patients had died and two (2.2%) were lost to follow-up. The 23-year Kaplan-Meier survival rates were 91.5% (95% confidence intervals (CI) 85.4% to 97.6%; 55 hips at risk) and 80.3% (95% CI, 71.8% to 88.7%; 48 hips at risk) respectively, with revision of the femoral stem or of any component as endpoints. At the time of this review, 76 patients without stem revision were assessed clinically and radiologically (mean follow-up 24.0 years (21.5 to 26.5)). For the 76 unrevised hips the mean Harris hip score was 87.1 (65 to 97). Femoral osteolysis was detected in five hips (6.6%) only in Gruen zone 7. Undersized stems were at higher risk of revision owing to aseptic loosening (p = 0.0003). Patients implanted with the stem in a varus position were at higher risk of femoral cortical hypertrophy and thigh pain (p = 0.0006 and p = 0.0007, respectively). In our study, survival, clinical outcome and radiographic data remained excellent in the third decade after implantation. Nonetheless, undersized stems were at higher risk of revision owing to aseptic loosening.
BackgroundTotal knee arthroplasty (TKA) designs continue to be modified to optimize patient's outcome. This study was designed to compare clinical and radiological results of classic worldwide used TKA posterior-stabilized (PS) design to those of its recent evolution.MethodsA consecutive group of 100 patients undergoing TKA using a classic cemented fixed-bearing PS TKA system was matched by age, gender, body max index to 100 patients having the newer cemented fixed-bearing PS design, both by the same manufacturer. Patients were assessed preoperatively, at 12 months and at 24 months minimum follow-up (range, 24-46) in a standard prospective fashion. The outcome assessments used were the Oxford Knee Score, the Knee Society Score, range of motion, and a satisfaction survey. A 2-sample t test comparing the 2 groups was performed.ResultsNo patients were lost at follow-up. At 2-year follow-up, differences in clinical and radiological Knee Society Score (P = .09), Oxford Score (P = .08), and overall satisfaction rate did not reach statistical significance. Implant group 2 showed a statistically significant decrease in postoperative anterior knee pain (P = .006). At final follow-up, 16% of group 1 knees achieved > 130° flexion compared with 37% in group 2 (P = .0009). There were 2 revisions for any reason in group 1 and none in group 2.ConclusionsDesign modifications applied to the newer TKA system allowed greater flexion and lower patellofemoral complications but did not appear to achieve better overall clinical scores.
Background: Meniscal repair has become the treatment of choice for meniscal tears, especially in the subset of bucket-handle meniscal tears (BHMTs). However, a comprehensive estimate of the corresponding failure rate is not available, thus maintaining doubts about the healing potential of these tears. Furthermore, a wide range of factors to predict high failure rates have been reported but with conflicting evidence. Purpose: To determine the failure rate after arthroscopic repair of BHMTs as reported in the literature, compare this with the failure rate of simple meniscal tears extracted from the same studies, and analyze the influence of factors previously reported to be predictive of meniscal repair failure. Study Design: Systematic review and meta-analysis; Level of evidence, 4. Methods: A systematic search was conducted by 2 independent reviewers using principal bibliographic databases (PubMed, Scopus, Cochrane Library, and EMBASE). After a stepwise exclusion process, 38 articles met the inclusion criteria. Failure rate data were analyzed with a random-effects proportional meta-analysis (weighted for individual study size), and forest plots were constructed to determine any statistically significant differences between BHMTs versus simple tears (longitudinal, radial, or horizontal), medial versus lateral BHMTs, isolated procedures versus repairs with concomitant anterior cruciate ligament reconstruction, and tears in red-red versus red-white zones. Moreover, a meta-regression analysis was conducted to evaluate the effect of patient age and sex, suture technique (in-out or all-inside), time from injury to surgery, mean number of stitches, and length of follow-up on failure rates. Results: The pooled failure rate was 14.8% (95% CI, 11.3%-18.3%; I2 = 77.2%). A total of 17 studies provided failure rates of both BHMT repairs (46/311 repairs) and simple tear repairs (54/546 repairs), demonstrating a significantly higher failure rate for BHMT repairs (risk ratio [RR] = 1.50; 95% CI, 1.05-2.15; I2 = 0%; P = .03). Medial BHMT repairs (RR = 1.94; 95% CI, 1.25-3.01; I2 = 0%; P = .003) and isolated repairs (RR = 1.77; 95% CI, 1.15-2.72; I2 = 0%; P = .009) had statistically higher risk of failure, but no statistically significant difference was found between tears in red-red versus red-white zones. Among the other factors evaluated with meta-regression, only the mean number of stitches showed a statistically significant effect on failure rates. Conclusion: Based on the currently available literature, this systematic review provides a reasonably comprehensive analysis of failure rate after arthroscopic BHMT repair; failure is estimated to occur in 14.8% of cases. Medial tears and isolated repairs were the 2 major predictors of failure.
This study evaluated the influence of modern tibial baseplate designs when using the anterior tibial cortex as a primary rotational landmark for the tibial baseplate in TKA. Eighty patients undergoing TKA were randomized in two groups. Group 1 included 25 females and 15 males receiving a posterior-stabilized (PS) symmetric tibial baseplate while Group 2 included 24 females and 16 males receiving a PS anatomical tibial component. Identical surgical technique, including the use of the surgical transepicondylar femoral axis (sTEA) and the anterior tibial cortex (“Curve-on-Curve”) as rotational alignment landmarks, was used. All patients underwent CT evaluation performed with the knee in full extension. Three observers independently measured the rotational alignment of the tibial component in relation to the sTEA. The rotational alignment of the symmetric baseplate showed an average external rotation of 1.3° (minimum 5°, maximum −1°): 91% of the knees showed 0 ± 3° with respect to the surgical sTEA, being internally rotated in 20%. The rotational alignment of the anatomical baseplate showed an average external rotation of 4.1° (minimum 0.4°, maximum 8.9°): only 47.5% of the knees showed 0 ± 3°, being externally rotated in 100%. The difference between the two groups was statistically significant. This study confirms the reliability of the “Curve-on-Curve” technique as an adequate rotational alignment anatomical landmark in TKA: the use of an asymmetric tibial baseplate might lead to external rotation of the tibial component when this technique is intraoperatively chosen.
Purpose: this study was conducted to compare the quantity of intercondylar bone removed during femoral box osteotomy for implantation of three contemporary posterior stabilized (PS) total knee arthroplasty designs: Sigma PS (DePuy), Vanguard (Biomet) and Persona (Zimmer). Methods: we compared the maximum volumetric bone resection required for the housing of the PS mechanism of these three designs. Bone removal by each PS box cutting jig was three-dimensionally measured. The differences between the three designs were analyzed by the Kruskal-Wallis test. The Mann-Whitney U-test was used for pairwise comparisons. The level of significance was set at p<0.05. Results: for small-size implants, the average box osteotomy volume of Persona was significantly smaller than the Vanguard and Sigma PS volumes (p=0.003). The mean difference between Vanguard and Sigma PS (p=0.01) was also significant. For medium size implants, the mean difference between Persona and Sigma PS (p=0.008) and the mean difference between Vanguard and Sigma PS (p=0.01) were statistically significant. For large size implants, the mean difference between Vanguard and Sigma PS (p=0.01) and the mean difference between Sigma PS and Persona (p=0.008) were statistically significant. Conclusions: irrespective of implant size, the Persona cutting jig always resected significantly less bone than did Vanguard and Sigma PS. Clinical Relevance: although this study does not establish any clinical relevance of removing more or less bone at primary TKA, its results suggest that if a PS design is indicated, it is preferable to select a model which resects less distal femoral bone. JOINTS 2014;2(2):76-80 J oints
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.