2020
DOI: 10.4139/sfj.71.293
|View full text |Cite
|
Sign up to set email alerts
|

Relationship between the Reduction Behavior of Copper and Tin Oxide Films by Formic acid and Solder Wettability

Abstract: 2 Experimental Method 2. 1 Materials Copper plates (purity: >99.96%, size: 20 × 20 × 2 mm) and solder foils (SnAg3. 0 Cu 0.5, size: 10 × 12 × 0.07 mm) were used as samples for analyzing the oxide film and measuring the oxide film thickness. Solder foils (SnAg3. 0 Cu 0.5, size: 5 × 5 × 0.07 mm) and solder balls (SnAg3. 0 Cu 0.5, size:φ1.5 mm) were used for the evaluation of wettability. The rust preventive agent and working oil used during the processing of copper plates were completely removed by immersion and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 5 publications
0
2
0
Order By: Relevance
“…[21][22][23][24][25][26][27][28][29][30] In this study, we combined a spectroscopic ellipsometer with an originally designed vacuum chamber to study in situ the reduction of oxide films on copper plates and solder surfaces during formic acid exposure. 31,32) Furthermore, the data on the relationship between the reduction rate and copper plate temperature was obtained to determine the activation energy of the reduction of the copper oxide film by formic acid. Moreover, the reduction rate increased with increasing formic acid partial pressure.…”
Section: Introductionmentioning
confidence: 99%
“…[21][22][23][24][25][26][27][28][29][30] In this study, we combined a spectroscopic ellipsometer with an originally designed vacuum chamber to study in situ the reduction of oxide films on copper plates and solder surfaces during formic acid exposure. 31,32) Furthermore, the data on the relationship between the reduction rate and copper plate temperature was obtained to determine the activation energy of the reduction of the copper oxide film by formic acid. Moreover, the reduction rate increased with increasing formic acid partial pressure.…”
Section: Introductionmentioning
confidence: 99%
“…In situ analysis of the oxide film on a copper plate surface and a solder surface when exposed to formic acid was performed by combining a spectroscopic ellipsometer and an in-house designed vacuum chamber. 41,42) In this study, detailed data on the relationship between the reduction rate and the copper plate temperature and formic acid partial pressure were obtained by in situ spectroscopic ellipsometry analysis. In addition, the rate-determining step and the mechanism involved in the reduction reaction of the copper oxide film with formic acid were considered.…”
Section: Introductionmentioning
confidence: 99%